Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practice for Set-up, Calibration, and Quality Control of Instruments Used for Radioactivity Measurements
Automaticky preložený názov:
Štandardné praktiky pre Set-up, kalibrácia a kontrolu kvality nástrojov používaných na meranie rádioaktivity
NORMA vydaná dňa 1.6.2014
Označenie normy: ASTM D7282-14
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.6.2014
Kód tovaru: NS-38077
Počet strán: 25
Približná hmotnosť: 75 g (0.17 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
activity, alpha, beta, calibration, control chart, gamma, gas proportional, liquid scintillation, measurements, quality control, spectrometry,, ICS Number Code 17.240 (Radiation measurements)
Significance and Use | ||||||
5.1 This practice is consistent with a performance-based approach wherein the frequency of re-calibration and instrument testing is linked to a laboratory's continuing performance with its quality control results. Under the premise of this practice, a laboratory demonstrates that its instrument performance is acceptable for analyzing sample test sources. 5.2 When a laboratory demonstrates acceptable performance based on continuing instrument quality control data (that is, QC charts), batch QC samples (that is, blanks, laboratory control samples, replicates, matrix spikes, and other batch QC samples as may be applicable) and independent reference materials, traditional schedule-driven instrument recalibration is permissible but unnecessary. 5.3 When continuing instrument QC, batch QC, or independent reference material sample results indicate that instrument response has exceeded established control or tolerance limits, instrument calibration is required. Other actions related to sample analyses on the affected instruments may be required by the laboratory QM. 5.4 The data obtained while following this Practice will most likely reside in computer storage. This data remains in the computer storage where it is readily retrievable and as necessary is used to produce plots, graphs, spreadsheets and other types of displays and reports. Frequency and performance of data storage backup should be specified in the laboratory QM. |
||||||
1. Scope | ||||||
1.1 This practice covers consensus criteria for the calibration and quality control of nuclear instruments. This practice is provided for establishing appropriate quality control parameters at instrument startup, calibration of nuclear counting instruments and the continuing monitoring of quality control parameters. Calibrations are usually performed to establish the operating parameters of the instrument. This practice addresses the typically used nuclear counting instruments: alpha spectrometer, gamma spectrometer, gas proportional counter and liquid scintillation counter. 1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||
2. Referenced Documents | ||||||
|
Historická
1.11.2014
Historická
1.11.2012
Historická
1.1.2010
Historická
1.6.2013
Historická
1.1.2013
Historická
1.12.2010
Posledná aktualizácia: 2024-09-25 (Počet položiek: 2 350 354)
© Copyright 2024 NORMSERVIS s.r.o.