Standard Test Method for Screening Trichloroethylene (TCE)-Contaminated Media Using a Heated Diode Sensor (Includes all amendments And changes 8/17/2011).
Automaticky preložený názov:
Štandardná skúšobná metóda pre skríning trichlóretylénom ( TCE ) -Contaminated médií pomocou diódového senzor Vyhrievanie
NORMA vydaná dňa 1.10.2006
Označenie normy: ASTM D7203-06e1
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.10.2006
Kód tovaru: NS-37854
Počet strán: 14
Približná hmotnosť: 42 g (0.09 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
field screening, halogenated volatile organic compounds (HVOCs), heated diode sensor, soils, trichloroethylene (TCE), water, ICS Number Code 13.080.10 (Chemical characteristics of soil)
| 1. Scope | ||||
|
1.1 This test method describes procedures for screening media known to contain the halogenated volatile organic compound (HVOC), trichloroethylene (TCE). Procedure A is to be used for screening soil known to contain TCE and Procedure B is to be used for screening water known to contain TCE. 1.1.1 Both Procedures A and B involve measuring the TCE concentration in the headspace above a sample using a heated diode sensor device. From this measurement, an estimated concentration of TCE in the sample can be determined. Any TCE remaining in the sample is not measured. Any other HVOC present in the sample will be reported as TCE. 1.2 Procedure A can also be used for screening the headspace above a soil suspected of containing HVOC contamination to indicate the presence or absence of HVOC contamination in the soil. Procedure B can also be used for screening the headspace above a water suspected of containing HVOC contamination to indicate the presence or absence of HVOC contamination in the water. For both procedures, any HVOC contamination remaining in the soil or water is not detected by this test method. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the application of regulatory limitations prior to use. Note 1The diode sensor is heated to temperatures ranging between approximately 600 and 1000 C (see ) and as a result could be a source of ignition. |
||||
| 2. Referenced Documents | ||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2026-06-20 (Počet položiek: 2 283 412)
© Copyright 2026 NORMSERVIS s.r.o.