Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Measurement of Hindered Phenolic and Aromatic Amine Antioxidant Content in Non-zinc Turbine Oils by Linear Sweep Voltammetry
Automaticky preložený názov:
Štandardná skúšobná metóda pre meranie bránenej fenolových a aromatických amínov obsahom antioxidantov v non-zinok turbínových olejov Linear Sweep voltametria
NORMA vydaná dňa 1.5.2014
Označenie normy: ASTM D6971-09(2014)
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.5.2014
Kód tovaru: NS-37151
Počet strán: 6
Približná hmotnosť: 18 g (0.04 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
2,6-di-tert-butyl-4methylphenol, 2,6-di-tert-butylphenol, alkylated diphenylamine, aromatic amine antioxidant, hindered phenol antioxidant, in-service oils, linear sweep voltammetry, non-zinc turbine oils, phenyl alpha naphthylamine, turbine oil, ICS Number Code 75.160.20 (Liquid fuels)
Significance and Use | ||||||||||||||
4.1 The quantitative determination of hindered phenol and aromatic amine antioxidants in a new turbine oil measures the amount of these compounds that has been added to the oil as protection against oxidation. Beside phenols, turbine oils can be formulated with other antioxidants such as amines which can extend the oil life. In in-service oil, the determination measures the amount of original (hindered phenol and aromatic amine) antioxidants remaining after oxidation has reduced its initial concentration. This test method is not designed or intended to detect all of the antioxidant intermediates formed during the thermal and oxidative stressing of the oils, which are recognized as having some contribution to the remaining useful life of the in-service oil. Nor does it measure the overall stability of an oil, which is determined by the total contribution of all species present. Before making final judgment on the remaining useful life of the in-service oil, which might result in the replacement of the oil reservoir, it is advised to perform additional analytical techniques (as in accordance with Test Methods D6224 and D4378; see also Test Method D2272), having the capability of measuring remaining oxidative life of the in-service oil. 4.1.1 This test method is applicable to non-zinc type of turbine oils as defined by ISO 6743 Part 4, Table 1. These are refined mineral oils containing rust and oxidation inhibitors, but not antiwear additives. 4.2 The test is also suitable for manufacturing control and specification acceptance. 4.3 When a voltammetric analysis is obtained for a turbine oil inhibited with a typical synergistic mixture of hindered phenol and aromatic amine antioxidants, there is an increase in the current of the produced voltammogram between 8 to 12 s (or 0.8 to 1.2 V applied voltage) (see Note 1) for the aromatic amines, and an increase in the current of the produced voltammogram between 13 and 16 s (or 1.3 to 1.6 V applied voltage) (see Note 1) for the hindered phenols in the neutral acetone test solution (Fig. 1: Note 1: Voltages listed with respect to reference electrode. The voltammograms shown in Figs. 1 and 2 were obtained with a platinum reference electrode and a voltage scan rate of 0.1 V/s. 4.4 For turbine oil containing only aromatic amines as antioxidants, there will only be an increase in the current of the produced voltammogram between 8 to 12 seconds (or 0.8 to 1.2 V applied voltage) (see Note 1) for the aromatic amines, by using the neutral acetone test solution (first peak in Fig. 1). 4.5 For turbine oils containing only hindered phenolic antioxidants, it is preferable to use a basic alcohol test solution rather than the neutral acetone test solutions, as there is an increase in the current of the produced voltammogram between 3 to 6 seconds (or 0.3 to 0.6 V applied voltage) (see Note 1) in basic alcohol test solution (Fig. 2: 1.1 This test method covers the voltammetric determination of hindered phenol and aromatic amine antioxidants in new or in-service type non-zinc turbine oils in concentrations from 0.0075 mass % up to concentrations found in new oils by measuring the amount of current flow at a specified voltage in the produced voltammogram. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Historická
1.11.2012
Historická
15.6.2013
Historická
1.5.2014
Historická
15.6.2013
Historická
1.6.2012
Historická
1.11.2005
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-12-23 (Počet položiek: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.