Standard Test Method for Determination of Antioxidants and Erucamide Slip Additives in Polyethylene Using Liquid Chromatography (LC)
Automaticky preložený názov:
Štandardná skúšobná metóda pre stanovenie antioxidantov a erukamidu sklzu prídavných látok v polyetylénu Využitie kvapalinovej chromatografie (LC)
NORMA vydaná dňa 1.9.2011
Označenie normy: ASTM D6953-11
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.9.2011
Kód tovaru: NS-37111
Počet strán: 7
Približná hmotnosť: 21 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
additive, antioxidants, erucamide slip, extraction, polyethylene: Additives--plastics, Antioxidants, Erucamide (slip), Extraction methods, Performance--plastics, Polyethylene (PE) resins, Stabilizing additive, ICS Number Code 83.040.20 (Rubber compounding ingredients)
Significance and Use | ||||||||||||||||||
Separation and identification of stabilizers used in the manufacture of polyethylene resins are necessary in order to correlate performance properties with polymer composition. This test method provides a means to determine the polymer additives listed in Table 1 in polyethylene samples. This test method is capable of the determination of other antioxidants, but the stability of these during extraction has not been investigated. The additive extraction procedure is made effective by the relatively low solubility of the polymer sample in solvents generally used for liquid chromatographic analysis. In this method, isopropanol and cyclohexane were chosen because of their excellent extraction efficiencies as well as for safety reasons. Other solvents including ethylacetate, isobutanol, chloroform and methylene chloride can also be used. Methods other than refluxing that have been used to remove additives from the polymer matrix including pressurized liquid, microwave, ultrasonic, and supercritical fluid extractions. For the separation of the extracted additives, SFC and GC have been used successfully for several of the additives. Under optimum conditions, the lowest level of detection for an antioxidant is approximately 2 ppm. |
||||||||||||||||||
1. Scope | ||||||||||||||||||
1.1 This test method covers a liquid-chromatographic procedure for the separation of primary and secondary antioxidant and slip additives currently used in polyethylene plastics. These additives are extracted with either isopropanol (resin densities < 0.94 g/cm3) or cyclohexane (resin densities > 0.94 g/cm3) prior to liquid-chromatographic separation. The ultraviolet absorbance of the eluting compound(s) is measured and quantitation is performed using external calibration. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 9. Note 1—There is no known ISO equivalent to this standard. |
||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||
|
Historická
1.5.2012
Historická
1.5.2012
Historická
1.5.2012
Historická
1.1.2009
Historická
1.5.2012
Historická
1.5.2012
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2025-05-16 (Počet položiek: 2 200 115)
© Copyright 2025 NORMSERVIS s.r.o.