Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Pour Point of Petroleum Products (Robotic Tilt Method)
Automaticky preložený názov:
Štandardná skúšobná metóda pre Pour Point ropných produktov ( Robotic Tilt metóda )
NORMA vydaná dňa 15.12.2008
Označenie normy: ASTM D6892-03(2008)
Poznámka: NEPLATNÁ
Dátum vydania normy: 15.12.2008
Kód tovaru: NS-36910
Počet strán: 5
Približná hmotnosť: 15 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
automatic pour point, petroleum products, pour point, robotic tilt method, Automated pour point, Automated procedures--petroleum products analysis, Flow and flow rate--petroleum products, Petroleum blending operations, Petroleum products, Pour point, ICS Number Code 75.080 (Petroleum products in general)
| Significance and Use | ||||||||
|
The pour point of a petroleum product is an index of the lowest temperature of its utility for certain applications. Flow characteristics, such as pour point, can be critical for the correct operation of lubricating systems, fuel systems, and pipeline operations. Petroleum blending operations require precise measurement of the pour point. Test results from this test method can be determined at either 1 or 3°C intervals. This test method yields a pour point in a format similar to Test Method D 97 or IP 15, when the 3°C interval results are reported. Note 2—Since some users may wish to report their results in a format similar to Test Method D 97 or IP 15 (in 3°C intervals) the precision data were derived for the 3°C intervals. For statements on bias relative to Test Method D 97 or IP 15, see the research report. This test method has comparable repeatability and better reproducibility relative to Test Method D 97 or IP 15 as measured in the 1998 interlaboratory program (see Section 13).
|
||||||||
| 1. Scope | ||||||||
|
1.1 This test method covers the determination of the pour point of petroleum products by an automatic instrument that tilts the test jar to detect movement of the surface of the test specimen with an optical device, after being removed from a regulated, stepped-bath cooling jacket. 1.2 This test method is designed to cover the range of temperatures from −57 to +51°C; however, the range of temperatures included in the 1998 interlaboratory test program only covered the temperature range from −51 to −11°C. 1.3 Test results from this test method can be determined at either 1 or 3°C testing intervals. 1.4 This test method is not intended for use with crude oils. Note 1—The applicability of this test method on residual fuel samples has not been verified. For further information on the applicability, refer to 13.4. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||
| 2. Referenced Documents | ||||||||
|
Poskytovanie aktuálnych informácií o legislatívnych predpisoch vyhlásených v Zbierke zákonov od roku 1945.
Aktualizácia 2x v mesiaci !
Chcete vedieť viac informácii ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2026-07-24 (Počet položiek: 2 290 214)
© Copyright 2026 NORMSERVIS s.r.o.