Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Available Cyanide with Ligand Displacement and Flow Injection Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric Detection
Automaticky preložený názov:
Štandardná skúšobná metóda pre dispozícii Kyanid s ligandmi vymístění a Flow Injection Analysis (FIA) Využitie plynu Diffusion separáciu a detekciu amperometrickú
NORMA vydaná dňa 1.10.2009
Označenie normy: ASTM D6888-09
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.10.2009
Kód tovaru: NS-36873
Počet strán: 7
Približná hmotnosť: 21 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
amperometry, available cyanide, cyanide, cyanide amenable to chlorination, flow injection analysis, free cyanide, gas diffusion membrane, ligand exchange, silver electrode, weak acid dissociable cyanide, Amperometric titration, Cyanides, Flow injection analysis (FIA), Free cyanide, Gas diffusion, Ligand displacement, Pervaporation (PV), Weak acid-dissociable (WAD) cyanide, ICS Number Code 17.120.10 (Flow in closed conduits)
Significance and Use | ||||||||||||||
Cyanide and hydrogen cyanide are highly toxic. Regulations have been established to require the monitoring of cyanide in industrial and domestic wastes and surface waters. This test method is applicable for natural water, saline waters, and wastewater effluent. The method may be used for process control in wastewater treatment facilities. |
||||||||||||||
1. Scope | ||||||||||||||
1.1 This method is used to determine the concentration of available inorganic cyanide in an aqueous wastewater or effluent. The method detects the cyanides that are free (HCN and CN-) and metal-cyanide complexes that are easily dissociated into free cyanide ions. The method does not detect the less toxic strong metal-cyanide complexes, cyanides that are not “amenable to chlorination.” 1.2 Total cyanide can be determined for samples that have been distilled as described in Test Methods D 2036, Test Method A, Total Cyanides after Distillation. The cyanide complexes are dissociated and absorbed into the sodium hydroxide capture solution, which can be analyzed with this test method; therefore, ligand exchange reagents from Sections 8.12 and 8.13 would not be required when determining total cyanide after distillation. 1.3 This procedure is applicable over a range of approximately 2 to 400 μg/L (parts per billion) available cyanide. Higher concentrations can be analyzed by dilution or lower injection volume. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Note 2 and Section 9. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Historická
1.4.2014
Historická
1.5.2013
Historická
1.1.2014
Historická
15.6.2007
Historická
15.7.2013
Historická
1.10.2012
Posledná aktualizácia: 2024-11-22 (Počet položiek: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.