Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Low Levels of Coliphages in Water (Withdrawn 2015)
Automaticky preložený názov:
Štandardná skúšobná metóda pre nízke úrovne coliphages vo vode
NORMA vydaná dňa 1.4.2009
Označenie normy: ASTM D6734-01(2009)
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.4.2009
Kód tovaru: NS-36314
Počet strán: 6
Približná hmotnosť: 18 g (0.04 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
coliform bacteria, coliphage, fecal coliform bacteria, indicators of pollution, rapid tests, Coliform bacteria, Coliphage analysis, Fecal coliform bacteria, Organic compounds--water, Pollution, Rapid testing, Water quality monitoring, ICS Number Code 07.100.20 (Microbiology of water)
Significance and Use | ||||||||
Coliphage organisms may serve as indicators of fecal contamination. The presence of coliphages in water in the absence of a disinfectant indicates the probable presence of fecal contamination. The absolute relationship between the number of coliforms and coliphages in natural waters has not been conclusively demonstrated. Coliphages are generally more resistant than coliforms to chlorination and may have some advantage over coliforms as an indicator of treatment efficiency in disinfected waters. The detection of coliphages in a water sample depends upon the use of a sensitive host strain in the coliphage assay. Coliphages may be detected by this concentration procedure in 6.5 h to provide important same-day information on the sanitary quality of water. The lower detection limit of this concentration procedure is 1 coliphage per volume of water sample tested. |
||||||||
1. Scope | ||||||||
1.1 This test method covers the determination of coliphages infective for E. coli C in water. The test method is simple, inexpensive, and yields an indication of water quality within 6.5 h. This coliphage method can determine coliphages in water down to 1 coliphage per volume of water sampled. 1.2 The test method is applicable to natural fresh water samples and to settled, filtered or finished water samples. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||
2. Referenced Documents | ||||||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-11-13 (Počet položiek: 2 210 764)
© Copyright 2024 NORMSERVIS s.r.o.