Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Guide for Low Slope Insulated Roof Membrane Assembly Performance
Automaticky preložený názov:
Štandardné Sprievodca pre Low svahu Strešné izolačné Membrane zhromaždenia Performance
NORMA vydaná dňa 15.3.2008
Označenie normy: ASTM D6630-08
Poznámka: NEPLATNÁ
Dátum vydania normy: 15.3.2008
Kód tovaru: NS-35950
Počet strán: 4
Približná hmotnosť: 12 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
cyclical fatigue, dynamic puncture, felts, heat conditioning, moisture content, multiple ply, roofing membrane, single ply, static puncture, structural deck, temperature, thermal insulation, wind tear resistance, Decks, Low-sloped roofs, Performance--roofing materials, Puncture testing, Roofing membranes, Structural deck, Thermal insulating materials, ICS Number Code 91.100.50 (Binders. Sealing materials)
Significance and Use | ||||||||||||||||||||||||||||||
A roof assembly must work as a system. Any component of the roof assembly demonstrating an inherent weakness or inability to perform will diminish the roof system performance and service life expected. This guide lists minimum performance attributes required of low slope roof assemblies. Products not previously used as roof membrane materials require additional tests beyond the scope of this document. This guide is not intended for use on in-service roofing materials. Roof membranes and other components should conform to ASTM product standards, if available. |
||||||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||||||
1.1 This guide lists test methods intended to establish a minimum level of performance for insulated roof membrane assemblies, and lists pertinent design guidelines and installation methods in a unified manner. Material tests and evaluations are included with and without roof insulation. 1.2 It is not possible to establish a precise correlation between laboratory tests on roof assemblies and natural weathering due to variations in geographical climate, design, material and installation. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use. |
||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||
|
Historická
1.5.2013
Historická
15.8.2011
Historická
1.3.2013
Historická
1.12.2007
Historická
15.9.2007
Historická
1.5.2013
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-11-22 (Počet položiek: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.