Standard Practice for Laboratory Bias Detection Using Single Test Result from Standard Material
NORMA vydaná dňa 1.5.2021
Označenie normy: ASTM D6617-21
Dátum vydania normy: 1.5.2021
Kód tovaru: NS-1024662
Počet strán: 5
Približná hmotnosť: 15 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
accepted reference value, bias, check standard, consensus, power of test, probability of bias detection, type I error, type II error,, ICS Number Code 19.020 (Test conditions and procedures in general)
Significance and Use | ||||||
4.1?Laboratories performing petroleum test methods can use this practice to set an acceptable tolerance zone for infrequent testing of CS or CCS material, based on ?, and a desired Type I error, for the purpose of ascertaining if the test method is being performed without bias. 4.2?This practice can be used to estimate the power of correctly detecting bias of different magnitudes, given the acceptable tolerance zone set in 4.1, and hence, gain insight into the limitation of the true bias detection capability associated with this acceptable tolerance zone. With this insight, trade-offs can be made between desired Type I error versus desired bias detection capability to suit specific business needs. 4.3?The CS testing activities described in this practice are intended to augment and not replace the regular statistical monitoring of test method performance as described in Practice D6299. |
||||||
1. Scope | ||||||
1.1?This practice covers a methodology for establishing an acceptable tolerance zone for the difference between a single result obtained for a Check Standard (CS) from a single implementation of a test method using a single measurement system at a laboratory versus its Accepted Reference Value (ARV), based on user-specified Type I error, the user-established measurement system precision for the execution of the test method, the standard error of the ARV, and a presumed hypothesis that the measurement system as operated by the laboratory in the execution of the test method is not biased. Note 1:?Throughout this practice, the term user refers to the
user of this practice, and the term laboratory (see 1.1) refers to the organization or entity
that is performing the test method.
1.2?For the tolerance zone established in 1.1, a methodology is presented to estimate the probability that the single test result will fall outside the zone, in the event that the presumed hypothesis is not true and there is a bias (positive or negative) of a user-specified magnitude that is deemed to be of practical concern. 1.3?This practice is intended for ASTM Committee D02 test methods that produce results on a continuous numerical scale. 1.4?This practice assumes that the normal (Gaussian) model is adequate for the description and prediction of measurement system behavior when it is in a state of statistical control. Note 2:?While this practice does not cover scenarios in which
multiple results are obtained on the same CS under site precision
or repeatability conditions, the statistical concepts presented are
applicable. Users wishing to apply these concepts for the scenarios
described are advised to consult a statistician and to reference
the CS methodology described in Practice D6299.
1.5?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||