Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practice for On-Line Determination of Cation Conductivity in High Purity Water
Automaticky preložený názov:
Štandardné praktiky pre On-Line Stanovenie katiónov vodivosť vo vysokej čistote vody
NORMA vydaná dňa 1.5.2011
Označenie normy: ASTM D6504-11
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.5.2011
Kód tovaru: NS-35412
Počet strán: 6
Približná hmotnosť: 18 g (0.04 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
boiler cycle chemistry, cation conductivity, on-line, process measurement, Automated procedures--water analysis, Boiler cycle chemistry, Cation conductivity, High-purity water, Hydrogen ion exchange, Online monitoring (in water analysis), Process stream analysis, Sample conditioning, ICS Number Code 13.060.60 (Examination of water for physical properties)
Significance and Use | ||||||||||||||||||
Cation conductivity provides one of the most sensitive and dependable on-line means of detecting anionic contamination in the boiler/steam cycle, such as chlorides, sulfates, nitrates, bicarbonates, and organic acids, such as formic and acetic. High sensitivity is provided by intentionally eliminating the pH adjusting treatment chemical(s), for example, ammonia and amines, from the sample and converting remaining salt contaminants into their acid forms which are approximately three times as conductive. Guidelines on cation conductivity limits for various cycle chemistry and boiler types have been established by EPRI (2-4) and by ASME (5,6). The sample effluent from the cation exchange column also may be used, and in some cases is preferred, for ion chromatography or other anion measurements. |
||||||||||||||||||
1. Scope | ||||||||||||||||||
1.1 This practice describes continuous sample conditioning by hydrogen ion exchange and measurement by electrolytic conductivity. It is commonly known as cation conductivity measurement in the power industry although it is actually an indication of anion contamination in high purity water samples. Measurements are typically in a range less than 1 μS/cm. 1.2 The actual conductivity measurements are made using Test Method D5391. 1.3 This practice does not provide for separate determination of dissolved carbon dioxide. Refer to Test Methods D2186 and D4519. 1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||
|
Historická
1.2.2009
Historická
1.2.2014
Historická
15.6.2013
Historická
1.6.2013
Historická
1.2.2009
Historická
15.3.2014
Posledná aktualizácia: 2024-11-04 (Počet položiek: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.