Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Determination of Asphalt Fume Particulate Matter in Workplace Atmospheres as Benzene Soluble Fraction
Automaticky preložený názov:
Štandardná skúšobná metóda pre stanovenie Asphalt dym častíc je v ovzduší na pracovisku, ako benzén rozpustnú frakciu
NORMA vydaná dňa 1.4.2010
Označenie normy: ASTM D6494-99(2010)
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.4.2010
Kód tovaru: NS-35371
Počet strán: 4
Približná hmotnosť: 12 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
air monitoring, asphalt fume, benzene soluble fraction, sampling and analysis, workplace atmospheres, Asphalt fume particulate, Benzene--atmospheric analysis, Benzene soluble fraction, Workplace air/atmospheres, ICS Number Code 13.040.30 (Workplace atmospheres)
Significance and Use | ||||||||
Asphalt is a material used in the construction of roads and as a roofing material and sealant. This test method provides a means of evaluating exposure to asphalt fume in the working environment at the presently recommended exposure guidelines. The threshold limit value (TLV) for asphalt (petroleum) fumes is 5 mg/m3 8-h TWA, (1998 Threshold Limit Values and Biological Exposure Indices, ACGIH ). This procedure has been adapted from NIOSH Method 5023 (withdrawn prior to 4th edition (1994) and replaced in 1998 with NIOSH Method 5042) and OSHA Method 58 to reduce the level of background contamination providing better reproducibility. |
||||||||
1. Scope | ||||||||
1.1 This test method covers the determination of asphalt fume particulate matter (as benzene soluble fraction) and total particulate matter weight in workplace atmospheres using a polytetrafluoroethylene (PTFE) filter methodology. 1.2 This procedure has been adapted from NIOSH Method 5023 (withdrawn prior to 4th edition (1994) and replaced in 1998 with NIOSH Method 5042) and OSHA Method 58 to reduce the level of background contamination providing better reproducibility. 1.3 This procedure is compatible with high flow rate personal sampling equipment–0.5 to 2.0 L/min. It can be used for personal or area monitoring. 1.4 The sampling method develops a time-weighted average (TWA) sample and can be used to determine short-term exposure limit (STEL). 1.5 The applicable concentration range for the TWA sample is from 0.2 to 2.0 mg/m3. 1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For more specific precautionary statements, see Section 9. |
||||||||
2. Referenced Documents | ||||||||
|
Posledná aktualizácia: 2024-11-04 (Počet položiek: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.