Standard Guide for Testing Systems for Measuring Dynamic Responses of Carbon Monoxide Detectors to Gases and Vapors
Automaticky preložený názov:
Štandardné Guide pre testovanie systému pre meranie dynamických Reakcia oxidu uhoľnatého detektory plynov a pár
NORMA vydaná dňa 1.4.2012
Označenie normy: ASTM D6332-12
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.4.2012
Kód tovaru: NS-34704
Počet strán: 6
Približná hmotnosť: 18 g (0.04 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
alarm, carbon monoxide, chamber, clean air supply, control, detector, humidification, interference, testing system, verification, Carbon monoxide (CO), Chamber, Clean air supply, Dynamic analysis/testing, Dynamic chamber testing, Gases, Humidifiers/humidification, Static tests--air/atmospheric environments, Vapor phase analysis/processing--atmospheric, ICS Number Code 13.040.99 (Other standards related to air quality)
Significance and Use | ||||||||||||||
This guide provides information on testing systems and their components used for measuring responses of CO alarms or detectors subjected to gases, vapors, and their mixtures. Components of a testing system include a chamber, clean air supply module, humidification module, gas and vapor delivery module, and verification and control instrumentation. The CO detector is tested by sequential exposure to CO and interference gases at the specified challenge concentrations. A properly functioning alarm/detector will sound upon sufficient exposure to CO but will not sound upon any exposure to interference gases consistent with applicable standards (for example, IAS 6-96 (1) , UL 2034). |
||||||||||||||
1. Scope | ||||||||||||||
1.1 This guide describes testing systems used for measuring responses of carbon monoxide (CO) alarms or detectors subjected to gases, vapors, and their mixtures. 1.2 The systems are used to evaluate responses of CO detectors to various CO concentrations, to verify that the detectors alarm at certain specified CO concentrations, and to verify that CO detectors do not alarm at certain other specified CO concentrations. 1.3 The systems are used for evaluating CO detector responses to gases and vapors that may interfere with the ability of detectors to respond to CO. 1.4 Major components of such a testing system include a chamber, clean air supply module, humidification module, gas and vapor delivery module, and verification and control instrumentation. 1.5 For each component, this guide provides a comparison of different approaches and discusses their advantages and disadvantages. 1.6 The guide also presents recommendations for a minimum configuration of a testing system. 1.7 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.8 This guide does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For more specific safety precautionary information, see 6.2. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2025-01-24 (Počet položiek: 2 222 000)
© Copyright 2025 NORMSERVIS s.r.o.