Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Specification for Fully-Formulated Glycol Base Engine Coolant for Heavy-Duty Engines
Automaticky preložený názov:
Štandard Specification pre plne formulovaných glykolu Základné chladiacej kvapaliny pre motory veľkého výkonu
NORMA vydaná dňa 1.12.2010
Označenie normy: ASTM D6210-10
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.12.2010
Kód tovaru: NS-34245
Počet strán: 4
Približná hmotnosť: 12 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Chladicí prostředky. Mrazicí prostředky. Mrazuvzdorné prostředky
Keywords:
cavitation, fully-formulated heavy-duty engine coolant, supplemental coolant additive maintenance dose, Cavitation corrosion resistance, Chemicals--specifications, Engine coolants/concentrates--specifications, Ethylene glycol--specifications, Fully formulated heavy duty engine coolant, Heavy-duty engine coolants--specifications, Supplemental coolant additive (SCA), ICS Number Code 71.100.45 (Refrigerants and antifreezes)
1. Scope | ||||||||||||||||
1.1 This specification covers the requirements for fully-formulated glycol base coolants for cooling systems of heavy-duty engines. When concentrates are used at 40 to 60 % glycol concentration by volume in water of suitable quality, (see Appendix X1), or when prediluted glycol base engine coolants (50 volume % minimum) are used without further dilution, they will function effectively during both winter and summer to provide protection against corrosion, cavitation, freezing, and boiling. 1.2 This specification is intended to cover the requirements for engine coolants prepared from virgin or recycled ethylene or propylene glycol. Note 1—Committee D15 has not substantially studied the impact of using recycled glycols from sources such as:
1.3 The coolants governed by this specification are categorized as follows:
1.4 Coolant concentrates meeting this specification do not require any addition of Supplemental Coolant Additive (SCA) until the first maintenance interval when a maintenance dose of SCA is required to continue protection in certain heavy duty engine cooling systems, particularly those of the wet cylinder liner-in-block design. The SCA additions are defined by and are the primary responsibility of the engine manufacturer or vehicle manufacturer. If they provide no instructions, follow the SCA supplier's instructions. 1.5 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2025-01-03 (Počet položiek: 2 218 319)
© Copyright 2025 NORMSERVIS s.r.o.