Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Analysis of Phenol by Capillary Gas Chromatography
Automaticky preložený názov:
Štandardná skúšobná metóda pre analýzu fenolu pomocou kapilárnej plynovej chromatografie
NORMA vydaná dňa 1.12.2008
Označenie normy: ASTM D6142-08
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.12.2008
Kód tovaru: NS-33981
Počet strán: 6
Približná hmotnosť: 18 g (0.04 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
2-methylbenzofuran, acetone, acetophenone, alfa-methylstyrene, cumene, gas chromatography, hydroxyacetone, mesityl oxide, m & p-cresol, o-cresol, phenol, sec-butyl alcohol, Gas chromatography (GC)--paints/related coatings/materials, Acetone, Acetophenone, Capillary gas chromatography, Cumene (isopropylbenzene), Hydroxyacetone analysis, Mesityl oxide, Methylbenzofuran, Methylstyrene, Phenol, ICS Number Code 71.040.50 (Physicochemical methods of analysis)
| Significance and Use | ||||||||||||||||
|
This test method is suitable for setting specifications on phenol and for use as an internal quality control tool where phenol is produced or is used in a manufacturing process. It may also be used in development or research work involving phenol. It is generally applied to determining those commonly occurring impurities such as mesityl oxide, cumene, hydroxyacetone, acetone, alpha-methylstyrene, 2-methylbenzofuran, acetophenone, o-cresol, and m & p-cresol. Purity is commonly reported by subtracting the determined expected impurities from 100.00. However, a gas chromatographic analysis cannot determine absolute purity if water is present or unknown components are contained within the material being examined. |
||||||||||||||||
| 1. Scope | ||||||||||||||||
|
1.1 This test method covers the determination of known impurities in phenol by gas chromatography (GC). It is generally meant for the analysis of phenol of 99.9 % or greater purity. 1.2 This test method has been found applicable over impurity concentrations of 15 to 70 mg/kg. Users of this method believe it is linear over a wider range. 1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E 29. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 9. |
||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2026-08-18 (Počet položiek: 2 297 400)
© Copyright 2026 NORMSERVIS s.r.o.