Standard Test Method for Analysis of Phenol by Capillary Gas Chromatography
Automaticky preložený názov:
Štandardná skúšobná metóda pre analýzu fenolu pomocou kapilárnej plynovej chromatografie
NORMA vydaná dňa 10.2.2003
Označenie normy: ASTM D6142-03
Poznámka: NEPLATNÁ
Dátum vydania normy: 10.2.2003
Kód tovaru: NS-33980
Počet strán: 6
Približná hmotnosť: 18 g (0.04 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
acetone, cumene, gas chromatography, hydroxyacetone, mesityl oxide, ICS Number Code 71.040.50 (Physicochemical methods of analysis)
| Significance and Use | ||||||||||||||||
|
This test method is suitable for setting specifications on phenol and for use as an internal quality control tool where phenol is produced or is used in a manufacturing process. It may also be used in development or research work involving phenol. It is generally applied to determining those commonly occurring impurities such as mesityl oxide, cumene, hydroxyacetone, acetone, alpha-methylstyrene, 2-methylbenzofuran, acetophenone, o-cresol, and m & p-cresol. Purity is commonly reported by subtracting the determined expected impurities from 100.00. However, a gas chromatographic analysis cannot determine absolute purity if unknown components are contained within the material being examined. |
||||||||||||||||
| 1. Scope | ||||||||||||||||
|
1.1 This test method covers the determination of known impurities in phenol by gas chromatography (GC). It is generally meant for the analysis of phenol of 99.9% or greater purity. 1.2 The following applies to all specified limits in this test method: for purposes of determining conformance with this test method, an observed value or calculated value shall be rounded off "to the nearest unit" in the last right-hand digit used in expressing the specification limit in accordance with the rounding-off method of Practice E 29. Precision data is based on impurity concentrations of 15 to 70 mg/kg. Users of this test method believe it is linear over a wider range. 1.3 This Test Method does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 9. |
||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||
|
Chcete mať istotu o platnosti využívaných predpisov?
Ponúkame Vám riešenie, aby ste mohli používať stále platné (aktuálne) legislatívne predpisy
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2026-08-18 (Počet položiek: 2 297 400)
© Copyright 2026 NORMSERVIS s.r.o.