Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practice for Subsurface Site Characterization of Test Pits for On-Site Septic Systems (Includes all amendments And changes 8/16/2017).
Automaticky preložený názov:
Štandardná prax pre podpovrchovej Site Charakteristika skúšobného jamy na mieste hnisavé systémy
NORMA vydaná dňa 13.10.1998
Označenie normy: ASTM D5921-96e1
Poznámka: NEPLATNÁ
Dátum vydania normy: 13.10.1998
Kód tovaru: NS-33085
Počet strán: 16
Približná hmotnosť: 48 g (0.11 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
septic system, site characterization, soil classification, soil description, visual classification, ICS Number Code 13.060.30 (Sewage water)
1. Scope | ||||||||||||||||||||
1.1 This practice covers procedures for the characterization of subsurface soil conditions at a site as part of the process for evaluating suitability for an on-site septic system. This practice provides a method for determining the usable unsaturated soil depth for septic tank effluent to infiltrate for treatment and disposal. 1.2 This practice describes a procedure for classifying soil by field observable characteristics within the United States Department of Agriculture, Soil Conservation Service (SCS) classification system. The SCS classification system is defined in Refs (1-4), not in this practice. This practice is based on visual examination and manual tests that can be performed in the field. This practice is intended to provide information about soil characteristics in terms that are in common use by soil scientists, public health sanitarians, geologists, and engineers currently involved in the evaluation of soil conditions for septic systems. 1.3 This procedure can be augmented by Test Method D 422, when verification or comparison of field techniques is required. Other standard test methods that may be used to augment this practice include: Test Methods D 2325, D 3152, D 5093, D 3385, and D 2434. 1.4 This practice is not intended to replace Practice D 2488 which can be used in conjunction with this practice if construction engineering interpretations of soil properties are required. 1.5 This practice should be used in conjunction with D 5879 to determine a recommended field area for an on-site septic system. Where applicable regulations define loading rates-based soil characteristics, this practice, in conjunction with D 5925, can be used to determine septic tank effluent application rates to the soil. 1.6 This practice should be used to complement standard practices developed at state and local levels to characterize soil for on-site septic systems. 1.7 The values stated in SI units are to be regarded as the standard. 1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-11-04 (Počet položiek: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.