Standard Test Method for (Analytical Procedure) Determining Transmissivity of Confined Nonleaky Aquifers by Critically Damped Well Response to Instantaneous Change in Head (Slug)
Automaticky preložený názov:
Štandardná skúšobná metóda pre ( analytický postup ) stanovenie priepustnosti stiesnenom Nonleaky aquiferov kriticky tlmený Well reakciu na okamžité zmeny vo Head ( Slug )
NORMA vydaná dňa 1.1.2000
Označenie normy: ASTM D5881-95(2000)
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.1.2000
Kód tovaru: NS-32929
Počet strán: 9
Približná hmotnosť: 27 g (0.06 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
aquifers, aquifer tests, ground water, hydraulic conductivity, observation wells, slug test, storage, coefficient, transmissivity, ICS Number Code 07.060 (Geology. Meteorology. Hydrology)
| 1. Scope | ||||||||||||
|
1.1 This test method covers determination of transmissivity from the measurement of water-level response to a sudden change of water level in a well-aquifer system characterized as being critically damped or in the transition range from underdamped to overdamped. Underdamped response is characterized by oscillatory changes in water level; overdamped response is characterized by return of the water level to the initial static level in an approximately exponential manner. Overdamped response is covered in Guide D4043; underdamped response is covered in D5785. 1.2 The analytical procedure in this test method is used in conjunction with Guide D4043 and the field procedure in Test Method D4044 for collection of test data. 1.3 The values stated in SI units are to be regarded as standard. 1.4 Limitations--Slug tests are considered to provide an estimate of the transmissivity of an aquifer near the well screen. The method is applicable for systems in which the damping parameter, [zeta], is within the range from 0.2 through 5.0. The assumptions of the method prescribe a fully penetrating well (a well open through the full thickness of the aquifer) in a confined, nonleaky aquifer. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||
| 2. Referenced Documents | ||||||||||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.