Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for (Analytical Procedure) for Determining Transmissivity and Storage Coefficient of Confined Nonleaky or Leaky Aquifer by Constant Drawdown Method in Flowing Well
Automaticky preložený názov:
Štandardná skúšobná metóda pre (analytické metódy) na stanovenie priepustnosti a skladové Koeficient obmedzených Nonleaky alebo Deravý Aquifer Constant prepad metódou v tečúcej Well
NORMA vydaná dňa 15.3.2013
Označenie normy: ASTM D5855-95(2013)
Poznámka: NEPLATNÁ
Dátum vydania normy: 15.3.2013
Kód tovaru: NS-32805
Počet strán: 5
Približná hmotnosť: 15 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
aquifers, aquifer tests, control wells, groundwater, observation wells, storage coefficient, transmissivity, ICS Number Code 13.060.10 (Water of natural resources)
Significance and Use | ||||||||
5.1 Assumptions—Leaky Aquifer: 5.1.1 Drawdown (sW) in the control well is constant, 5.1.2 Well is infinitesimal diameter and fully penetrates aquifer, 5.1.3 The aquifer is homogeneous, isotropic, and areally extensive, and 5.1.4 The control well is 100 % efficient. 5.2 Assumptions—Nonleaky Aquifer: 5.2.1 Drawdown (sW) in the control well is constant, 5.2.2 Well is infinitesimal diameter and fully penetrates aquifer, 5.2.3 The aquifer is homogeneous, isotropic, and areally extensive, 5.2.4 Discharge from the well is derived exclusively from storage in the nonleaky aquifer, and 5.2.5 The control well is 100 % efficient. 5.3 Implications of Assumptions: 5.3.1 The assumptions are applicable to confined aquifers and fully penetrating control wells. However, this test method may be applied to partially penetrating wells where the method may provide an estimate of hydraulic conductivity for the aquifer adjacent to the open interval of the well if the horizontal hydraulic conductivity is significantly greater than the vertical hydraulic conductivity. 5.3.2 Values obtained for storage coefficient are less reliable than the values calculated for transmissivity. Storage coefficient values calculated from control well data are not reliable. |
||||||||
1. Scope | ||||||||
1.1 This test method covers an analytical solution for determining transmissivity and storage coefficient of a leaky or nonleaky confined aquifer. It is used to analyze data on the flow rate from a control well while a constant head is maintained in the well. 1.2 This analytical procedure is used in conjunction with the field procedure in Practice D5786. 1.3 Limitations—The limitations of this technique for the determination of hydraulic properties of aquifers are primarily related to the correspondence between field situation and the simplifying assumption of the solution. 1.4 Units—The values stated in either SI Units or inch-pound units are to be regarded separately as standard. The values in each system may not be exact equivalents; therefore each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. Reporting of test results in units other than SI shall not be regarded as nonconformance with this test method. 1.5 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||
2. Referenced Documents | ||||||||
|
Posledná aktualizácia: 2024-12-23 (Počet položiek: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.