Standard Test Method for Chlorophenoxy Acid Herbicides in Waste Using HPLC
Automaticky preložený názov:
Štandardná skúšobná metóda pre chlorofenoxy Acid herbicídov v odpadoch za použitia HPLC
NORMA vydaná dňa 1.2.2006
Označenie normy: ASTM D5659-95(2006)
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.2.2006
Kód tovaru: NS-32063
Počet strán: 5
Približná hmotnosť: 15 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
chlorophenoxy acid herbicides, 2,4-D, 2,4,5-T, chlorophenoxy acid herbicides in waste, HPLC, Silvex, 2,4,5-TP, ICS Number Code 13.030.30 (Special wastes)
Significance and Use | ||
Phenoxy acid herbicides are used extensively for weed control. Esters and salts of 2,4-D, 2,4,5-T, and Silvex have been used for agricultural crop and lawn care. |
||
1. Scope | ||
1.1 This test method covers the analysis of 2,4-dichlorophenoxyacetic acid (2,4-D), 2,4,5-trichlorophenoxyacetic acid (2,4,5-T), and 2,4,5-trichlorophenoxypropionic acid (silvex) in liquids and solids, using high performance liquid chromatography with an ultraviolet detector (HPLC/UV). This test method is applicable for a concentration range from approximately 50 to 1000 ppm. This range takes into consideration the sample preparation and dilutions outlined in Section . Lower detection levels can be obtained by using larger sample sizes, smaller total final volumes, or with the use of in-line or solid phase extraction, concentration, and/or cleanup. 1.2 The chlorophenoxy herbicides may be present as a variety of salts or esters, which are converted to, analyzed, and reported as their respective acids. 1.3 This test method is applicable to liquid and solid waste and waste extract matrices including aqueous, oil, spent solvent, soil, ash, leachates, etc. 1.4 This test method may be applicable to other phenoxy acid herbicides. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section and for specific precautionary statements. |
||
2. Referenced Documents | ||
|