Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Determination of Volatile Organic Compounds in Atmospheres (Canister Sampling, Mass Spectrometry Analysis Methodology)
NORMA vydaná dňa 15.8.2021
Označenie normy: ASTM D5466-21
Dátum vydania normy: 15.8.2021
Kód tovaru: NS-1034435
Počet strán: 21
Približná hmotnosť: 63 g (0.14 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
ambient atmospheres, air analysis, canister analysis, canister sampling, gas chromatography–mass spectrometry, indoor atmospheres, volatile organic compounds, workplace atmospheres,, ICS Number Code 13.040.01 (Air quality in general)
Significance and Use | ||||||||||
5.1?VOCs are emitted into ambient, indoor, and workplace air from many different sources. These VOCs are of interest for a variety of reasons including participation in atmospheric chemistry and contributing to air toxics with their associated acute or chronic health impacts. 5.2?Canisters are particularly well suited for the collection and analysis of very volatile and volatile organic compounds because they collect whole gas samples. 5.3?Chemically stable selected VOCs have been successfully collected in passivated stainless steel canisters. Collection of atmospheric samples in canisters provides for: (5.4?Interior surfaces of the canisters may be treated by any of several proprietary passivation processes including an electropolishing process to remove or cover reactive metal sites on the interior surface of the vessel and a fused silica coating process. 5.5?For this test method, VOCs are defined as organic compounds that can be quantitatively recovered from the canisters having a vapor pressure greater than 10-2 kPa at 25?C (see Table 1 for examples). 5.6?Target compound polarity is also a factor in compound recovery. Aliphatic and aromatic hydrocarbons from C1 to C13 have been successfully measured with this test method but are not listed in Table 1 5.7?Recovery studies shall be conducted on VOCs not listed in Table 1 before expanding the use of this test method to include these additional compounds. Recovery from humidified spiked canisters shall agree with the spiked amount by ?30 %. The laboratory shall be responsible for verifying the relevant method performance characteristics for each compound added to the analyte list as agreed with their customer(s). The laboratory shall retain records of verification and make them available to customers upon request. Added VOCs (that is, those not listed in Table 1) shall be clearly identified in customer reports |
||||||||||
1. Scope | ||||||||||
1.1?This test method describes a procedure for sampling and analysis of selected volatile organic compounds (VOCs) in ambient, indoor, and workplace atmospheres. The test method is based on the collection of whole air samples in stainless steel canisters with specially treated (passivated) interior surfaces. 1.2?For sample analysis, a portion of the sample is subsequently removed from the canister and the collected VOCs are selectively concentrated by adsorption or condensation onto a trap, subsequently released by thermal desorption, separated by gas chromatography, and measured by a low resolution mass spectrometric detector. This test method describes procedures for sampling into canisters to final pressures both above and below atmospheric pressure (respectively referred to as pressurized and subatmospheric pressure sampling).2 1.3?This test method is applicable to specific VOCs that have been determined to be stable when stored in canisters (see Table 1). Numerous compounds, many of which are chlorinated VOCs, have been successfully tested for storage stability in pressurized canisters (1-4).3 Information on storage stability is also available for polar compounds 1.4?The procedure for collecting the sample involves the use of inlet lines, air filters, flow rate regulators for obtaining time-integrated samples, and in the case of pressurized samples, an air pump. Typical long-term fixed location canister samplers have been designed to automatically start and stop the sample collection process using electronically actuated valves and timers 1.5?The organic compounds that have been successfully measured single-digit micrograms per cubic metre (?g/m3 (or single digit parts-per-billion by volume (ppbv)) concentration with this test method are listed in order of approximate retention time in Table 1. The test method is applicable to VOC concentrations ranging from the detection limit to approximately 1000 ?g/m3 (300 ppbv). Above this concentration, smaller sample aliquots of sample gas may be analyzed or samples can be diluted with dry ultra-high-purity nitrogen or air or equivalent. 1.6?The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.7?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Safety practices should be part of the users SOP manual. 1.8?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||
2. Referenced Documents | ||||||||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-11-01 (Počet položiek: 2 208 817)
© Copyright 2024 NORMSERVIS s.r.o.