Standard Test Method for Evaluation of Durability of Rock for Erosion Control Under Freezing and Thawing Conditions
Automaticky preložený názov:
Štandardná skúšobná metóda pre hodnotenie trvanlivosti Rock for Protierózne Podľa zmrazovania a rozmrazovania podmienky
NORMA vydaná dňa 15.1.2013
Označenie normy: ASTM D5312/D5312M-12(2013)
Poznámka: NEPLATNÁ
Dátum vydania normy: 15.1.2013
Kód tovaru: NS-30697
Počet strán: 6
Približná hmotnosť: 18 g (0.04 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Zemní práce. Hloubicí práce. Budování základů. Podzemní práce
Keywords:
armor stone, breakwater stone, climatic setting, erosion control, freeze-thaw, gabion-fill, laboratory testing, riprap, rock, rock material properties, ICS Number Code 93.020 (Earth works. Excavations. Foundation construction. Underground works)
Significance and Use | ||||||||||||||||
5.1 Rock for erosion control consists of individual pieces of natural stone. The ability of these individual pieces of stone to resist deterioration due to weathering action affects the stability of the integral placement of rock for erosion control and hence, the stability of construction projects, structures, shorelines, and stream banks. 5.2 This test method is designed to determine the effects of freezing and thawing action on the individual pieces of rock for erosion control and the resistance of the rock to deterioration. This test method was developed to be used in conjunction with additional test methods listed in Practice D4992. This test method does not provide an absolute value but rather an indication of the resistance to freezing and thawing; therefore, the results of this test method are not to be used as the sole basis for the determination of rock durability. 1.1 This test method covers the
procedures for evaluating the durability of rock for erosion
control when exposed to freezing and thawing conditions on slabs of
rock. This weathering test exposes the rock to freezing and thawing
cycles similar to natural weather conditions. The rock slabs,
prepared in accordance with procedures in Practice D5121, are
intended to be representative of erosion control rock and its
weaknesses. The test is appropriate for breakwater stone, armor
stone, riprap, and gabion sized rock materials.
The limitations of the test are twofold. First the size of the cut rock slab specimens may eliminate some of the internal defects present in the rock structure. The test specimens may not be representative of the quality of the larger rock samples used in construction. Careful examination of the rock source and proper sampling are essential in minimizing this limitation. Secondly the test requires the rock slabs to be exposed to up to 55 freezing-thawing cycles. The test is time intensive and may require up to two or more months to complete the sample preparation, testing, and analysis portions of the procedure. 1.2 The use of reclaimed concrete and other materials is beyond the scope of this test method. 1.3 Units—The values stated in either SI units or inch-pound units [presented in brackets] are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.4 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026, unless superseded by this standard. 1.4.1 For purposes of comparing measured or calculated value(s) with specified limits, the measured or calculated value(s) shall be rounded to the nearest decimal or significant digits in the specified limits. 1.4.2 The procedures used to specify how data are collected/recorded or calculated, in this standard are regarded as the industry standard. In addition, they are representative of the significant digits that generally should be retained. The procedures used do not consider material variation, purpose for obtaining the data, special purpose studies, or any considerations for the user’s objectives; and it is common practice to increase or reduce significant digits of reported data to be commensurate with these considerations. It is beyond the scope of this standard to consider significant digits used in analytical methods for engineering design. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Historická
1.2.2013
Historická
1.9.2007
Historická
15.2.2007
Historická
1.7.2008
Historická
15.1.2011
Historická
1.11.2011
Posledná aktualizácia: 2024-11-22 (Počet položiek: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.