Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Determining Transmissivity and Storage Coefficient of Bounded, Nonleaky, Confined Aquifers
Automaticky preložený názov:
Štandardné skúšobnú metódu pre stanovenie Transmisivita a skladovanie Koeficient ohraničený , Nonleaky , Napäté kolektory
NORMA vydaná dňa 10.10.1996
Označenie normy: ASTM D5270-96
Poznámka: NEPLATNÁ
Dátum vydania normy: 10.10.1996
Kód tovaru: NS-30533
Počet strán: 7
Približná hmotnosť: 21 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
Aquifers, Boundaries, Confined aquifers, Control wells, Drawdown, Field testing-ground water/aquifers, Ground water, Hydraulic conductivity, Image wells, Observation wells, Storativity, Transmissivity, transmissivity-aquifers (bounded/nonleaky/confined), analytical
1. Scope | ||||||||||||||
1.1 This test method covers an analytical procedure for determining the transmissivity, storage coefficient, and possible location of boundaries for a bounded confined aquifer. This test method is used to analyze water-level or head data from one or more observation wells or piezometers during the pumping of water from a control well at a constant rate. This test method also applies to flowing artesian wells discharging at a constant rate. With appropriate changes in sign, this test method also can be used to analyze the effects of injecting water into a control well at a constant rate. 1.2 The analytical procedure in this test method is used in conjunction with the field procedure in Test Method D4050. 1.3 Limitations -The valid use of this test method is limited to determination of transmissivities and storage coefficients for aquifers in hydrogeologic settings with reasonable correspondence to the assumptions of the Theis nonequilibrium method (see Test Method D4106) (see 5.1), except that the aquifer is limited in areal extent by a linear boundary that fully penetrates the aquifer. The boundary is assumed to be either a constant-head boundary (equivalent to a stream or lake that hydraulically fully penetrates the aquifer) or a no-flow (impermeable) boundary (equivalent to a contact with a significantly less permeable rock unit). The Theis nonequilibrium method is described in Test Methods D 4105 and D 4106. 1.4 The values stated in SI units are to be regarded as standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-12-22 (Počet položiek: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.