Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Determining Triaxial Compression Creep Strength of Chemical Grouted Soils
Automaticky preložený názov:
Štandardná skúšobná metóda pre stanovenie Triaxiál Kompresný medza pevnosti chemických preliaty pôd
NORMA vydaná dňa 10.5.1997
Označenie normy: ASTM D5202-91(1997)
Poznámka: NEPLATNÁ
Dátum vydania normy: 10.5.1997
Kód tovaru: NS-30262
Počet strán: 5
Približná hmotnosť: 15 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
Chemical-grouted soil, Compression testing-soil, Creep, Design strength, Loading tests-soil, Long term strength, Mohr stress circles, Shear testing-soil/rock, Structural applications-soil, Triaxial compression, Young´s modulus, triaxial compression creep strength of chemical grouted soils, test, ICS Number Code 93.020 (Earth works. Excavations. Foundation construction. Underground works)
| 1. Scope | ||||||||||||||||||
|
1.1 This test method covers the determination of long term strength and deformation of a cylindrical specimen of either a (undisturbed) field sample or laboratory-fabricated chemical grouted soil when it is sheared undrained in compression under a constant sustained load. Note 1-The voids of chemical grouted soils are most often substantially filled with grout. Thus, pore pressures are unlikely to develop. This test method is not applicable to partially grouted soils in which substantial pore pressures may develop. If pore pressures must be measured, reference is made to Test Method D4767 for equipment and procedures.1.2 This test method provides data useful in determining strength and deformation properties of chemical grouted soils subjected to sustained loads. Mohr strength envelopes may also be determined. 1.3 The determination of strength envelopes and the development of relationships to aid in interpreting and evaluating test results are left to the engineer or office requesting the test. 1.4 The values stated in either SI or inch-pound units shall be regarded separately as standard. The values in each system may not be exact equivalents, therefore, each system must be used independently of the other, without combining values in any way. 1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||
|
Posledná aktualizácia: 2026-09-04 (Počet položiek: 2 300 131)
© Copyright 2026 NORMSERVIS s.r.o.