Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Determination of Chloride, Nitrate, and Sulfate in Atmospheric Wet Deposition by Chemically Suppressed Ion Chromatography
Automaticky preložený názov:
Štandardná skúšobná metóda pre stanovenie chloridu , dusičnan a síran atmosférického mokré depozície chemicky potlačený iónovou chromatografiou
NORMA vydaná dňa 1.1.1995
Označenie normy: ASTM D5085-95
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.1.1995
Kód tovaru: NS-29779
Počet strán: 9
Približná hmotnosť: 27 g (0.06 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
Anions content, Atmospheric analysis, Chloride content, Hail, Ion chromatography, Ion exchange chromatography, Method detection limit (MDL), Nitrate (ion) content, Rain, Sleet, Snow, Sulfate content, chloride/nitrate/sulfate in atmospheric wet deposition, by chemically, suppressed ion chromatography, test, ICS Number Code 07.060 (Geology. Meteorology. Hydrology), 71.040.40 (Chemical analysis)
| 1. Scope | ||||||||||||||||||||||
|
1.1 This test method is applicable to the determination of chloride, nitrate, and sulfate in atmospheric wet deposition (rain, snow, sleet, and hail) by chemically suppressed ion chromatography (1) using a two pen variable setting recorder and integrator. For additional applications refer to Test Method D4327. 1.2 The concentration ranges for this test method are listed below. The range tested was confirmed using the interlaboratory collaborative test (see Table 1 for statistical summary of the collaborative test). Range of Range Method Tested MDL (mg/L)(2) (mg/L) (mg/L) Chloride 0.03 0.09-2.0 0.15-1.36 Nitrate 0.03 0.09-5.0 0.15-4.92 Sulfate 0.03 0.09-8.0 0.15-6.521.3 The method detection limit (MDL) is based on single operator precision (2) and may be higher or lower for other operators and laboratories. The precision and bias data presented are insufficient to justify use at this low level, however, many workers have found that this test method is reliable at lower levels than those that were tested. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 9. |
||||||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||||||
|
Posledná aktualizácia: 2026-09-08 (Počet položiek: 2 300 134)
© Copyright 2026 NORMSERVIS s.r.o.