Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Determining Unreacted Monomer Content of Latexes Using Gas-Liquid Chromatography
Automaticky preložený názov:
Štandardná skúšobná metóda pre stanovenie nezreagovaný monomér Obsah Latex pomocou plynovej chromatografie
NORMA vydaná dňa 1.2.2008
Označenie normy: ASTM D4747-02(2008)
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.2.2008
Kód tovaru: NS-28415
Počet strán: 4
Približná hmotnosť: 12 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
analysis of monomers, acrylic latexes chromatography (subheading gas chromatography), gas chromatography, latex paints, latex vehicles, styrene, trace monomers, unreacted monomers in latexes, Gas chromatography (GC)--paints/related coatings/materials, Odor--chemicals, Trace elements--paints/related coatings/materials, n-Butyl acrylate/methacrylate, Free monomers, Hydrocarbons, Latex paints, Latex vehicles, Methyl methacrylate plastics, Monomr content, Polymerization, Styrene
| Significance and Use | ||||
|
Excessive amounts of unreacted monomer may cause concerns relating to toxicity and odor. This test method is designed to measure the unreacted monomer content of latexes. The results may be used to monitor the extent of polymerization during manufacture, as well as to establish maximum unreacted monomer content for regulatory purposes. |
||||
| 1. Scope | ||||
|
1.1 This test method covers the determination of free monomer content of acrylic latexes. Monomers that have been successfully determined by this procedure include n-butyl methacrylate, n-butyl acrylate, styrene, and methyl methacrylate. The determination of other monomers has not been evaluated, but this test method is believed to be applicable. The established working range of this test method is from 100 to 1000 μg/g, but there is no reason to believe it will not work outside of this range, provided that appropriate dilutions and adjustments in specimen size are made. 1.2 The volatile composition of acrylic latexes is expected to change with time and environmental factors. This time dependence of the determination may be seen as an artificially large deviation of results, making the method mostly applicable for in-house quality control, where sampling and analysis conditions can be better controlled. 1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section 7 for specific hazard statements. |
||||
| 2. Referenced Documents | ||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2026-09-04 (Počet položiek: 2 300 131)
© Copyright 2026 NORMSERVIS s.r.o.