Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Methods for Electrical Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable (Includes all amendments And changes 5/28/2014).
Automaticky preložený názov:
Štandardné skúšobné metódy na elektrické vlastnosti výkon izoláciou a bundy pre telekomunikačné káble a vodiče
NORMA vydaná dňa 1.11.2008
Označenie normy: ASTM D4566-08e1
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.11.2008
Kód tovaru: NS-27726
Počet strán: 29
Približná hmotnosť: 87 g (0.19 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
aging, attenuation, attenuation to crosstalk ratio near-end, attenuation to crosstalk ratio far-end, capacitance deviation, capacitance difference, capacitance unbalance pair-to-pair, capacitance unbalance pair-to-ground, capacitance unbalance pair-to-support wire, characteristic impedance, coaxial capacitance, conductor resistance, conductor resistance unbalance, continuity, conversion loss, crosses, crosstalk loss&mdash,far end, crosstalk loss&mdash,near end, dc proof test
| Significance and Use | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Electrical tests, properly interpreted, provide information with regard to the electrical properties of the insulation. The electrical test values give an indication as to how the insulation will perform under conditions similar to those observed in the tests. Electrical tests may provide data for research and development, engineering design, quality control, and acceptance or rejection under specifications. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 1. Scope | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
1.1 These test methods cover procedures for electrical testing of thermoplastic insulations and jackets used on telecommunications wire and cable and for the testing of electrical characteristics of completed products. To determine the procedure to be used on the particular insulation or jacket compound, or on the end product, reference should be made to the specification for the product. 1.2 The test methods appear in the following sections of this standard:
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Sections 6 and 37. 4.1 In-process electrical tests are used primarily as process control tools in an attempt to minimize the number and magnitude of problems detected at final test of completed cable. 9.1 Electrical tests of completed wire and cable may include verification of some or all of the properties in accordance with Sections 11 through 51. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2026-09-04 (Počet položiek: 2 300 131)
© Copyright 2026 NORMSERVIS s.r.o.