Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practice for Sampling of Geosynthetics for Testing
Automaticky preložený názov:
Štandardná prax pre odber vzoriek geosyntetík pre Testovanie
NORMA vydaná dňa 15.1.2009
Označenie normy: ASTM D4354-99(2009)
Poznámka: NEPLATNÁ
Dátum vydania normy: 15.1.2009
Kód tovaru: NS-26925
Počet strán: 3
Približná hmotnosť: 9 g (0.02 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
geosynthetic, quality assurance, quality control, sampling, specification conformance, testing, Geosynthetics--sampling, ICS Number Code 59.080.70 (Geotextiles)
| Significance and Use | ||||||||||||||||||||||||||||||||||||||||||||
|
This practice provides a means by which samples of geosynthetics may be selected to provide a statistically valid sample for the selection of test specimens without previous knowledge of the variability that may exist between production units. The principles stated in Practice D 4271, and the illustrative text in that practice can be used by test method authors in preparing sampling statements. This practice gives three procedures for sampling: one for manufacturer's quality control (MQC), one for manufacturer's quality assurance (MQA) testing, and a third for purchaser's specification conformance testing. For this reason, test methods containing a section on sampling that requires the use of this practice should contain a statement in the section on reporting similar to the following:“ Report which procedure from Practice D 4354 was used for sampling: Procedure A for Manufacturer's Quality Control (MQC), Procedure B for Manufacturer's Quality Assurance (MQA) Testing, or Procedure C for Purchaser's Specification Conformance Testing. Manufacturer's Quality Assurance is done internally to ensure the manufacturer of the MQC program. When it is required to provide certification to a purchaser as to quality assurance, the MQA testing is to be done by an external MQA testing facility. |
||||||||||||||||||||||||||||||||||||||||||||
| 1. Scope | ||||||||||||||||||||||||||||||||||||||||||||
|
1.1 This practice covers three procedures for the sampling of geosynthetics for testing. This practice requires that instructions on taking laboratory samples and test specimens be part of every test method for geosynthetics. 1.1.1 The first procedure describes the sampling of production units for the purpose of manufacturer's quality control (MQC) (Table 1). 1.1.2 The second procedure describes the sampling of production units for the purpose of manufacturer's quality assurance (MQA) testing during the manufacturing process. This requires that backup statistical process control records be maintained during the manufacturing process (Table 2). 1.1.3 The third procedure describes the division of shipments of geosynthetics into lots and the determination of lot sample size for purchaser's specification conformance testing (Table 3). 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. TABLE 1 Number of Units to be Selected as Lot Sample—Purchaser's Specification Conformance
TABLE 2 Number of Units to be Selected as Lot Sample—Manufacturer's Quality Assurance
TABLE 3 Number of Units to be Selected as Lot Sample—Purchaser's Specification Conformance
|
||||||||||||||||||||||||||||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||||||||||||||||||||||||||||
|