Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Residual Acrylonitrile Monomer Styrene-Acrylonitrile Copolymers and Nitrile Rubber by Headspace Gas Chromatography (Withdrawn 2010) (Includes all amendments And changes 12/31/2010).
Automaticky preložený názov:
Štandardná skúšobná metóda pre zbytkový akrylonitrilu monomér styrén - akrylonitril a nitrilkaučuk od Headspace plynovej chromatografie ( Withdrawn 2010 )
NORMA vydaná dňa 1.1.2001
Označenie normy: ASTM D4322-96(2001)e1
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.1.2001
Kód tovaru: NS-26838
Počet strán: 8
Približná hmotnosť: 24 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
headspace gas chromatography, nitrile rubber, residual acrylonitrile, styrene-acrylonitrile copolymers, ICS Number Code 83.060 (Rubber)
Significance and Use | ||||||
For various reasons one may wish to measure the amount of unreacted or residual acrylonitrile monomer in styrene-acrylonitrile copolymers, nitrile rubbers, or ABS terpolymers. Under optimum conditions, the lowest level of detection of AN in SAN or ABS copolymers and NBR rubbers is approximately 0.5 ppm for the packed column test method and 3 ppm for the capillary test method. |
||||||
1. Scope | ||||||
1.1 This test method is suitable for determining the residual acrylonitrile (RAN) content of styrene-acrylonitrile (SAN) copolymer, rubber-modified acrylonitrile-butadiene-styrene (ABS) resins, and nitrile rubber (NBR). 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 9. Note 1--Although the packed column option of this test method and ISO 4581:1994 (E) differ in some details, data obtained using either test method should be technically equivalent. There is no equivalent ISO standard for the capillary column option of this test method. |
||||||