Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Determination of Vibrated Bulk Density of Calcined Petroleum Coke
Automaticky preložený názov:
Štandardná skúšobná metóda pre stanovenie vibroval objemová hustota pálenej ropného koksu
NORMA vydaná dňa 1.7.2010
Označenie normy: ASTM D4292-10
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.7.2010
Kód tovaru: NS-26711
Počet strán: 5
Približná hmotnosť: 15 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
calcined petroleum coke, porosity, vibrated bulk density, Coal/coke products, Compaction measurement, Density--petroleum products, Bulk density, Petroleum coke, Volumetric measurement--petroleum products, ICS Number Code 75.160.10 (Solid fuels)
Significance and Use | ||||||||||||||||
Vibrated bulk density, VBD, is an indicator of calcined petroleum coke porosity, which affects its suitability for use in pitch-bonded carbon applications. (Warning—Vibrated bulk density for a sample of calcined petroleum coke is strongly dependent upon average particle size and particle size range. Bulk density tends to increase with decreasing coke size. A narrow particle size range for this test minimizes the possibility for variation due to skewing of the test sample toward either screen defining the sample. Particle size range tested should be agreed upon by the purchaser and supplier.) Note 1—An example of the use of VBD to characterize coke for prebaked anodes for aluminum smelting is reported by Belitskus who found particles passing through a 0.59-mm opening, No. 30, sieve and retained on a 0.30-mm opening, No. 50, sieve to be preferred. Other popular ranges are particles passing through a 2.36-mm opening, No. 8, sieve and retained on a 1.17-mm opening, No. 16, sieve for the continuous Soderberg anode process and particles passing through a 6.68-mm opening sieve (equivalent to a 3-mesh Tyler Standard Series) and retained on a 3.33-mm opening, No. 6, sieve for graphite electrode manufacture. |
||||||||||||||||
1. Scope | ||||||||||||||||
1.1 This test method covers the determination of bulk density of a representative 2-kg sample of calcined petroleum coke, after vibration to increase compaction. 1.2 The procedure is limited to particles passing through a 6.68-mm opening sieve (equivalent to a 3-mesh Tyler Standard Series) and retained on a 0.21-mm opening sieve (equivalent to a 65-mesh Tyler Standard Series). Further, the procedure is limited to a specific test sample having particles retained between screens having openings that differ by a factor of less than 2 and preferably less than 2. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Historická
1.9.2008
Historická
1.9.2008
Historická
1.9.2008
Historická
1.9.2008
Historická
1.6.2013
Historická
15.8.2013
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-11-22 (Počet položiek: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.