Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practice for Sampling Phytoplankton with Water-Sampling Bottles (Withdrawn 2020)
Automaticky preložený názov:
Štandardné praktiky pre vzorkovanie Phytoplankton s vodou, odber vzoriek Fľaše
NORMA vydaná dňa 1.9.2012
Označenie normy: ASTM D4136-82(2012)
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.9.2012
Kód tovaru: NS-26181
Počet strán: 2
Približná hmotnosť: 6 g (0.01 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
ICS Number Code 07.100.20 (Microbiology of water)
Significance and Use | ||
4.1 The advantages of water-sampling bottles are as follows: 4.1.1 Samples of known volume can be obtained from a precise depth. 4.1.2 A quantitative sample is obtained. Nanno- and ultraplankton are not lost from the sampling device. 4.1.3 A sampler of almost any desired volume or construction material can be obtained. 4.1.4 The sampler is light-weight and can be used without auxiliary equipment. 4.1.5 There is a free flow of water through the cylinder of the sampler when it is being lowered. 4.1.6 Samplers can be arranged serially to facilitate sampling at several depths almost simultaneously. 4.1.7 The sampler can be used in most depths of water. 4.2 The disadvantages of water-sampling bottles are as follows: 4.2.1 Samples are obtained from only discrete depths; they cannot be obtained from horizontal or vertical strata of water. 4.2.2 The samplers cannot be used satisfactorily in fast-flowing water. 4.3 There are several special considerations that shall be observed when using water-sampling bottles. They are as follows: 4.3.1 The samplers should be protected from damage, which commonly results in leakage. 4.3.2 Following use, the samplers should be hung open in a horizontal position to allow for thorough drying. 4.3.3 The end stoppers should be inspected periodically for signs of wear or deterioration and replaced as necessary (1.1 This practice covers the procedures for obtaining quantitative samples of a phytoplankton community by use of water-sampling bottles. 1.2 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||
2. Referenced Documents | ||
|
Historická
1.3.2013
Historická
1.12.2012
Historická
1.9.2010
Historická
1.12.2012
Historická
1.10.2011
Historická
1.12.2012
Posledná aktualizácia: 2024-12-21 (Počet položiek: 2 216 840)
© Copyright 2024 NORMSERVIS s.r.o.