Standard Test Method (Analytical Procedure) for Determining Transmissivity of Nonleaky Confined Aquifers by Overdamped Well Response to Instantaneous Change in Head (Slug Tests)
Automaticky preložený názov:
Štandardná skúšobná metóda ( analytický postup ) na stanovenie priepustnosti Nonleaky Napäté kolektory podľa přetlumenému stochastickému Well Reakcia na okamžité zmeny v hlave ( Slug testy)
NORMA vydaná dňa 1.11.2004
Označenie normy: ASTM D4104-96(2004)
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.11.2004
Kód tovaru: NS-26057
Počet strán: 4
Približná hmotnosť: 12 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
aquifers, aquifer tests, control wells, ground water, hydraulic conductivity, observation wells, storage coefficient storativity, transmissivity, ICS Number Code 13.060.10 (Water of natural resources)
| 1. Scope | ||||||||||
|
1.1 This test method covers the determination of transmissivity from the measurement of force-free (overdamped) response of a well-aquifer system to a sudden change of water level in a well. Force-free response of water level in a well to a sudden change in water level is characterized by recovery to initial water level in an approximate exponential manner with negligible inertial effects. 1.2 The analytical procedure in this test method is used in conjunction with the field procedure in Test Method D 4044 for collection of test data. 1.3 LimitationsSlug tests are considered to provide an estimate of transmissivity. Although the assumptions of this test method prescribe a fully penetrating well (a well open through the full thickness of the aquifer), the slug test method is commonly conducted using a partially penetrating well. Such a practice may be acceptable for application under conditions in which the aquifer is stratified and horizontal hydraulic conductivity is much greater than vertical hydraulic conductivity. In such a case the test would be considered to be representative of the average hydraulic conductivity of the portion of the aquifer adjacent to the open interval of the well. 1.4 The values stated in SI units are to be regarded as standard. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
| 2. Referenced Documents | ||||||||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2026-08-28 (Počet položiek: 2 298 625)
© Copyright 2026 NORMSERVIS s.r.o.