Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Purgeable Organic Compounds in Water Using Headspace Sampling
Automaticky preložený názov:
Štandardná skúšobná metóda pre Purgeable organických látok vo vode pomocou headspace Odber vzoriek
NORMA vydaná dňa 1.5.2011
Označenie normy: ASTM D3871-84(2011)
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.5.2011
Kód tovaru: NS-25161
Počet strán: 8
Približná hmotnosť: 24 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
drinking water, gas chromatography, purge and trap, volatile organic compounds, Dynamic headspace analysis, Organic compounds--water, Purgeable organic compounds, Sampling water analysis applications, Wastewater testing/treatment, ICS Number Code 13.060.50 (Examination of water for chemical substances)
Significance and Use | ||||||||
Purgeable organic compounds, including organohalides, have been identified as contaminants in raw and drinking water. These contaminants may be harmful to the environment and man. Dynamic headspace sampling is a generally applicable method for concentrating these components prior to gas chromatographic analysis (1 to 5). This test method can be used to quantitatively determine purgeable organic compounds in raw source water, drinking water, and treated effluent water. |
||||||||
1. Scope | ||||||||
1.1 This test method covers the determination of most purgeable organic compounds that boil below 200°C and are less than 2 % soluble in water. It covers the low μg/L to low mg/L concentration range (see Section 15 and Appendix X1). 1.2 This test method was developed for the analysis of drinking water. It is also applicable to many environmental and waste waters when validation, consisting of recovering known concentrations of compounds of interest added to representative matrices, is included. 1.3 Volatile organic compounds in water at concentrations above 1000 μg/L may be determined by direct aqueous injection in accordance with Practice D2908. 1.4 It is the user's responsibility to assure the validity of the test method for untested matrices. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in 8.5.5.1. |
||||||||
2. Referenced Documents | ||||||||
|
Historická
15.2.2013
Historická
1.9.2012
Historická
1.10.2008
Historická
1.5.2011
Historická
1.6.2012
Historická
1.2.2009
Chcete mať istotu o platnosti využívaných predpisov?
Ponúkame Vám riešenie, aby ste mohli používať stále platné (aktuálne) legislatívne predpisy
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-11-04 (Počet položiek: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.