Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practice for Calculation and Adjustment of the Langelier Saturation Index for Reverse Osmosis
NORMA vydaná dňa 1.7.2019
Označenie normy: ASTM D3739-19
Dátum vydania normy: 1.7.2019
Kód tovaru: NS-953936
Počet strán: 4
Približná hmotnosť: 12 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
CaCO3 scale, Langelier saturation index, LSI, reverse osmosis, scaling,, ICS Number Code 07.030 (Physics. Chemistry)
Significance and Use | ||||||||||||||||||
5.1 In the design and operation of RO installations, it is important to predict the calcium carbonate scaling properties of the concentrate stream. Because of the increase in total dissolved solids in the concentrate stream and the difference in passages for calcium ion, bicarbonate ion, and free carbon dioxide, the calcium carbonate scaling properties of the concentrate stream will generally be quite different from those of the feed solution. This practice permits the calculation of the Langelier saturation index for the concentrate stream from the feed water analyses and the RO operating parameters. 5.2 A positive Langelier saturation index indicates the tendency to form a calcium carbonate scale, which can be damaging to RO performance. This practice gives various procedures for the adjustment of the Langelier saturation index. 5.3 The tendency to form calcium carbonate scale can be suppressed by the addition of antiscalents or crystal modifiers. Suppliers of antisealents and crystal modifiers can provide information on the scale inhibition peformance of these types of chemical. Their use may be appropriate for reducing scale formation in RO systems. The RO system supplier should be consulted prior to the use of antisealents and crystal modifiers to ensure they will not have a negative impact on the RO system. |
||||||||||||||||||
1. Scope | ||||||||||||||||||
1.1 This practice covers the calculation and adjustment of the Langelier saturation index for the concentrate stream of a reverse osmosis (RO) device. This index is used to determine the need for calcium carbonate (CaCo1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||
|
Posledná aktualizácia: 2024-11-04 (Počet položiek: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.