Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Methods for Accumulated Deposition in a Steam Generator Tube
NORMA vydaná dňa 1.11.2022
Označenie normy: ASTM D3483-14(2022)
Dátum vydania normy: 1.11.2022
Kód tovaru: NS-1096716
Počet strán: 7
Približná hmotnosť: 21 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
boiler, deposit, deposition, rifled, steam generator tube, boiler, deposit, deposition, rifled, steam generator tube, boiler, deposit, deposition, glass bead, rifled, steam generator tube,, ICS Number Code 27.040 (Gas and steam turbines. Steam engines)
Significance and Use | ||||||||||||||
4.1?The weight per unit area measurement is an indication of the relative cleanliness or dirtiness of the boiler. It is used to determine the effectiveness of the boiler chemical treatment program and to determine the need for chemically cleaning the boiler systems. Allowing the internal deposition to accumulate unchecked will likely lead to boiler tube failures by mechanisms of under deposit corrosion and tube metal overheating. |
||||||||||||||
1. Scope | ||||||||||||||
1.1?These test methods cover the determination of the weight per unit area of waterside deposits on heat-transfer surfaces of steam generator tubes. The following test methods are included:
1.2?Test Method A is a procedure generally applicable to deposits ranging from 1 to 100 g/ft2. The precision was determined in the collaborative study over the range of 16 to 76 g/ft2. This procedure allows the discretionary selection of the area on the tube to be sampled. The removed deposit allows for further chemical analysis. 1.3?Test Method B is a procedure generally applicable to deposits ranging from 1 to 100 g/ft2. The precision was determined in a collaborative study over the range of 28 to 73 g/ft2. The procedure averages out the heavier and lighter deposited areas. The solvent solution produced allows for further chemical analysis. 1.4?Test Method C is a procedure generally applicable to deposits ranging from 1 to 100 g/ft2. The precision was determined in a collaborative study over the range of 17 to 88 g/ft2. The procedure averages out the heavier and lighter deposited areas. The removed deposit does not allow for further chemical analysis. 1.5?These test methods have been generally evaluated on the types of waterside deposits generally found on heat-transfer surfaces of steam generator tubes. It is the users responsibility to ensure the validity of these test methods for other types of deposits or high temperature scale. 1.6?These methods are sometimes used for accumulated deposition in rifled steam generator tubes. Experience has shown that there is a significant difference in the deposition in the grooves and on the lands on some rifled steam generator tubes. The grooves have been shown to hold more deposit. Test Method B and Test Method C will average out this difference. In Method A the choice exists, either to choose to remove the deposition from the groove if it is visually determined to be more heavily deposited, or to remove equally over the grooves and lands. It is important that it be understood what choices were made and that the report reflect the choices made when using Test Method A on rifled steam generator tubes. 1.7?There are some steam generator tubes where it is apparent that half of the tube is exposed to the flame from the external appearance, this side is typically called the fireside or hot side. The other half of the tube is not exposed to the flame from the external appearance is typically called the casing side or cold side. These test methods also require that the tube be split in half, so the tube is generally split along these lines. On these tubes it is generally found that more internal deposition exists on the fireside or hot side. Some users of these methods will determine the deposition only on side where it appears visually that more deposition exists. Some users will determine the deposition on both sides and report the results separately and some will average the two results. It is important that the user of the data be aware of the choices made and that the report of the results be specific. 1.8?The values stated in either SI or inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.9?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.10?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Chcete mať istotu o platnosti využívaných predpisov?
Ponúkame Vám riešenie, aby ste mohli používať stále platné (aktuálne) legislatívne predpisy
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-11-04 (Počet položiek: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.