Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practices for Sampling Water from Closed Conduits
Automaticky preložený názov:
Štandardné postupy pre odber vzoriek vody z uzavretých potrubiach
NORMA vydaná dňa 1.12.2010
Označenie normy: ASTM D3370-10
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.12.2010
Kód tovaru: NS-23446
Počet strán: 11
Približná hmotnosť: 33 g (0.07 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
back pressure regulator, pressure reducer, sample cooler, sampling, sampling equipment, variable rod-in-tube orifice, water, Back pressure regulator, Chelation, Closed conduits, Equipment (for sampling water), Field testing--water, Graphite furnace atomic absorption spectrometry (GFAAS), Pressure reduction, Radioactive water analysis, Sample cooler, Sampling water analysis applications, Variable rod-in-tube orifice, Water analysis, ICS Number Code 13.060.30 (Sewage water)
Significance and Use | ||||||||||||||||||||||||||||
The goal of sampling is to obtain for analysis a portion of the main body of water that is representative. The most critical factors necessary to achieve this are points of sampling, and materials selection, system design, time of sampling, frequency of sampling, and proper procedures to maintain the integrity of the sample prior to analysis. Homogeneity of the process to be sampled is frequently lacking, necessitating multiple-point sampling. If it is impractical to utilize a most-representative sampling point, it may be practical to determine and understand interrelationships so that results obtained at a minimum number of points may be used to characterize the system. Samples collected from a single point in a system are always recognized as being non-representative to some degree. For this reason, total representativeness of samples cannot be a prerequisite to the selection of a sampling point. The degree of representativeness of the sample shall be assessed and the assessment made a part of the permanent record. This will prevent an artificial degree of accuracy from being assigned to the data derived from tests on the sample. The samples shall be of sufficient volume and shall be taken frequently enough to permit reproducibility of testing requisite for the desired objective, as required by the method of analysis to be used. Laboratories or facilities conducting water sampling should be in compliance with Guide D3856. |
||||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||||
1.1 These practices cover the equipment and methods for sampling water from closed conduits such as process streams at power stations for chemical, physical, microbiological, and radiological analyses. It does not cover specialized equipment required for and unique to a specific test or method of analysis. The following are included: |
||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||
|
Historická
1.1.2013
Historická
1.12.2012
Historická
1.12.2012
Historická
1.12.2012
Historická
1.12.2012
Historická
1.10.2011
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-12-23 (Počet položiek: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.