Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Methods for Analysis for Fluoride Content of the Atmosphere and Plant Tissues (Semiautomated Method)
Automaticky preložený názov:
Štandardné skúšobné metódy pre analýzu pre obsah fluoridov vo atmosféry a rastlinných tkanív (poloautomaticky metóda)
NORMA vydaná dňa 1.10.2013
Označenie normy: ASTM D3270-13
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.10.2013
Kód tovaru: NS-23092
Počet strán: 10
Približná hmotnosť: 30 g (0.07 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
ambient atmospheres, colorimetric determination of fluoride, fluoride, potentiometric determination of fluoride, ICS Number Code 13.040.20 (Ambient atmospheres)
Significance and Use | ||||||||||||||
5.1 These test methods may be used for determining the fluoride content of particulate matter and gases collected from the atmosphere by passive and active means, including plant tissues. The user is warned that the fluoride content of passive collectors (including plants) give only qualitative or semiquantitative measurement of atmospheric fluoride content. |
||||||||||||||
1. Scope | ||||||||||||||
1.1 These test methods describe the semiautomated procedure for the analyses of various types of samples for the purpose of determining total fluoride. Since the test methods incorporate microdistillation of the sample, they may be applied to any fluoride-containing solution where standards of identical composition have been carried through the same sample preparation procedures and have proven to provide quantitative recovery when analyzed by the semiautomated system. Conversely, the methods shall not be applied for analyses until the applicability has been demonstrated. 1.2 In normal use, the procedure can detect 0.1 μg/mL of F. The normal range of analysis is from 0.1 to 1.6 μg/mL of F. Higher concentrations can be analyzed by careful dilution of samples with reagent water. If digested samples routinely exceed 1.6 μg/mL of F, the analytical portion of the pump manifold can be modified to reduce sensitivity. However, the best procedure is to analyze a smaller aliquot of the sample. Most accurate results are obtained when the fluoride concentration falls in the middle or upper part of the calibration curve. 1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.4 This standard does not
purport to address all of the safety concerns, if any, associated
with its use. It is the responsibility of the user of this standard
to establish appropriate safety and health practices and determine
the applicability of regulatory limitations prior to use.
Standard Terminology Relating to Sampling
and Analysis of Atmospheres (Includes all amendments and changes
9/7/2020). Standard Guide for Laboratories Engaged
in Sampling and Analysis of Atmospheres and Emissions Standard Test Method for Separation and
Collection of Particulate and Gaseous Fluorides in the Atmosphere
(Sodium Bicarbonate-Coated Glass Tube and Particulate Filter
Method) Standard Test Method for Separation and
Collection of Particulate and Water-Soluble Gaseous Fluorides in
the Atmosphere (Filter and Impinger Method) Standard Test Method for Automated
Separation and Collection of Particulate and Acidic Gaseous
Fluoride in the Atmosphere (Double Paper Tape Sampler Method) Standard Test Methods for Analysis for
Fluoride Content of the Atmosphere and Plant Tissues (Manual
Procedures) (Withdrawn 2010) Standard Specification for Reagent
Water |
Historická
1.4.2007
Historická
1.4.2012
Historická
1.10.2011
Historická
1.4.2012
Historická
1.10.2011
Historická
1.10.2011
Posledná aktualizácia: 2024-12-21 (Počet položiek: 2 216 840)
© Copyright 2024 NORMSERVIS s.r.o.