Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Separation and Collection of Particulate and Gaseous Fluorides in the Atmosphere (Sodium Bicarbonate-Coated Glass Tube and Particulate Filter Method)
Automaticky preložený názov:
Štandardná skúšobná metóda pre separáciu a zvoz pevných častíc a plynných fluoridy v atmosfére ( Hydrogénuhličitan sodný - Coated sklenené trubice a filter častíc metóda )
NORMA vydaná dňa 1.10.2005
Označenie normy: ASTM D3268-91(2005)
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.10.2005
Kód tovaru: NS-23086
Počet strán: 6
Približná hmotnosť: 18 g (0.04 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
ambient atmospheres, analysis, fluoride, gaseous fluoride, particulate fluoride, sampling, ICS Number Code 13.040.20 (Ambient atmospheres)
| Significance and Use | ||||||||||||||
|
The sodium bicarbonate coated tube filter method provides a means of separating and collecting atmospheric gaseous fluoride and particulate fluoride samples. Since the samples are collected on the dry tube and filter, the fluoride may be eluted with a small volume of eluant (see Section 10 for specific instructions on fluoride elution). Elution into a small volume and the sensitivity of the analytical methods employed allow the analysis of the collected fluoride to fractional parts of a microgram per cubic metre on samples taken for a 12-h period. |
||||||||||||||
| 1. Scope | ||||||||||||||
|
1.1 The sodium bicarbonate-coated glass tube and membrane filter method provides a means for the separation and collection of gaseous atmospheric forms of fluoride reactive with sodium bicarbonate and particulate forms of fluoride which are collected by a filter. The test method is applicable to 12-h sampling periods, collecting 1 to 500 g of gaseous fluoride at a 15 L/min [0.5 ft3/min] sampling rate or about 0.1 to 50 g/m 3. The length of the sampling period can therefore be adjusted so that the amount of fluoride collected will fall within this range. The actual lower limit of the test method will depend upon the sensitivity of the analytical method employed and the quality of reagents used in tube preparation and analysis. It is recommended that the lower limit of detection should be considered as two times the standard deviation of the monthly arithmetic mean blank value. Any values greater than the blank by less than this amount should be reported as "blank value." 1.2 The values stated in SI units are to be regarded as standard. The inch-pound units in brackets may be approximate. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||
| 2. Referenced Documents | ||||||||||||||
|
Posledná aktualizácia: 2026-08-14 (Počet položiek: 2 293 479)
© Copyright 2026 NORMSERVIS s.r.o.