Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Methods for Aromatics in Mineral Spirits by Gas Chromatography
Automaticky preložený názov:
Štandardné testovacie metódy pre aromatických látok v minerálnymi destiláty plynovou chromatografiou
NORMA vydaná dňa 10.6.2001
Označenie normy: ASTM D3257-01
Poznámka: NEPLATNÁ
Dátum vydania normy: 10.6.2001
Kód tovaru: NS-23038
Počet strán: 8
Približná hmotnosť: 24 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
aromat in mineral spirits, ethylbenzene in mineral spirits, gas chromatography (GC), mineral spirits, ICS Number Code 87.060.30 (Solvents)
| 1. Scope | ||||||||
|
1.1 These test methods cover the determination of ethylbenzene and total eight-carbon (C8) and heavier aromatics in the concentration range from 0.1 to 30 % in mineral spirits having a distillation range from 149 to 210oC (300 to 410oF) as determined by Test Method D86. The procedures permit the identification and calculation of concentrations of aromatic components to 0.1 volume %. 1.2 It is recognized by analytical chemists that a single column gas chromatography analysis of an unknown sample is risky. In such cases, multiple and different analytical techniques must be used for absolutely positive identification, for example, several different gas chromatography columns, gas chromatography/mass spectrometer, or gas chromatography/infrared, etc. In these test methods the material is known and is clearly defined. 1.3 Oxygenated compounds, if present, may interfere and cause erroneous results. Such oxygenated compounds are not normally present in mineral spirits. 1.4 Three test methods are covered as follows: 1.4.1 Test Method A, measurement of ethylbenzene content, C8 plus higher aromatics (except ethylbenzene), and total aromatics by means of a single packed column gas chromatographic analysis. 1.4.2 Test Method B, measurement of ethylbenzene content by means of a rapid packed column gas chromatographic analysis. 1.4.3 Test Method C, measurement of ethylbenzene content, C8 plus higher aromatics (except ethylbenzene) and total aromatics by means of a capillary column gas chromatographic analysis. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.6 For hazard information and guidance, see the supplier's Material Safety Data Sheet. |
||||||||
| 2. Referenced Documents | ||||||||
|
Poskytovanie aktuálnych informácií o legislatívnych predpisoch vyhlásených v Zbierke zákonov od roku 1945.
Aktualizácia 2x v mesiaci !
Chcete vedieť viac informácii ? Pozrite sa na túto stránku.