Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Open-Cell Content of Rigid Cellular Plastics by the Air Pycnometer (withdrawn 2006)
Automaticky preložený názov:
Štandardná skúšobná metóda pre Open - Cell Obsah tuhých ľahčených plastov, ktoré letecký piknometra ( stiahnuté 2006 )
NORMA vydaná dňa 10.7.1998
Označenie normy: ASTM D2856-94(1998)
Poznámka: NEPLATNÁ
Dátum vydania normy: 10.7.1998
Kód tovaru: NS-21723
Počet strán: 6
Približná hmotnosť: 18 g (0.04 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
Air pycnometer method, Cellular plast-rigid, Cell wall, Closed cell, Open cell, Pycnometer, Rigid cellular plast, Rigid plast, open cell content-rigid cellular plast, by air pycnometer, test, ICS Number Code 83.100 (Cellular materials)
1. Scope |
1.1 Cellular plastics are composed of the membranes or walls of polymer separating small cavities or cells. These cells may be interconnecting (open cell), non-connecting (closed cell), or any combination of these types. This test method determines numerical values for open cells. It is a porosity determination, measuring the accessible cellular volume of a material. The volume occupied by closed cells is considered to include cell walls. Since any conveniently sized specimen can only be obtained by some cutting operation, a fraction of the closed cells will be opened during sample preparation and will be included as open cells. 1.2 This test method consists of three procedures: 1.2.1 Procedure A , designed to correct for cells opened during sample preparation, by measuring cell diameter, calculating, and allowing for surface volume; 1.2.2 Procedure B , designed to correct for cells opened in sample preparation, by cutting and exposing new surface area equal to the surface area of the original sample dimension, and 1.2.3 Procedure C , which does not correct for cells opened during sample preparation and gives good accuracy on predominantly highly open-celled materials. The accuracy decreases as the closed cell content increases and as the cell size increases. 1.3 The values as stated in SI units are to be regarded as the standard. The values in parentheses are given for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Notes 2, 4, and 8. Note 1-This test method and ISO 4590-1981 use the same basic principles but are significantly different in experimental detail. |
Posledná aktualizácia: 2024-11-22 (Počet položiek: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.