Standard Specification for Crosslinked Polyethylene Insulation for Wire and Cable Rated 2001 to 35 000 V
Automaticky preložený názov:
Štandardné špecifikácie pre zosietený polyetylén izolácie pre káble a vodiče Menovitý 2001-35 000 V.
NORMA vydaná dňa 10.9.2000
Označenie normy: ASTM D2656-00
Poznámka: NEPLATNÁ
Dátum vydania normy: 10.9.2000
Kód tovaru: NS-21039
Počet strán: 3
Približná hmotnosť: 9 g (0.02 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
ac voltage, crosslinked polyethylene, dc voltage, heat distortion, hot creep, hot set, insulation resistance, water absorption, weather resistant, ICS Number Code 29.035.20 (Plastic and rubber insulating materials)
| 1. Scope | ||||||||||
|
1.1 This specification covers a crosslinked polyethylene insulation for electrical wires and cables for conductor sizes 8 AWG (8.37 mm2) and larger. The base polymer of this insulation consists substantially of polyethylene. 1.2 This type of insulation is suitable for use on power cables in wet and dry locations at conductor temperatures not exceeding 90oC for continuous operation, 130oC for emergency overload conditions, and 250C for short-circuit conditions. It is considered suitable for all sizes and voltage classifications of single- and multiple-conductor power cables at voltage ratings of 2001 to 35000 V phase-to-phase at the 100 % insulation level and at voltage ratings of 2001 to 25000 V at the 133 % insulation level as listed in Table 1C of Test Methods D470. 1.3 Materials covered by this specification are not sunlight- and weather-resistant unless they are carbon black pigmented or contain an additive system designed for this protection. 1.4 In many instances the insulation cannot be tested unless it has been formed around a conductor. Therefore, tests are done on insulated wire in this standard solely to determine the relevant property of the insulation and not to test the conductor or completed cable. 1.5 Whenever two sets of values are presented, in different units, the values in the first set are the standard, while those in parentheses are for information only. |
||||||||||
| 2. Referenced Documents | ||||||||||
|