Standard Test Methods for Determining the Izod Pendulum Impact Resistance of Plastics (Includes all amendments and changes 4/7/2023).
NORMA vydaná dňa 15.3.2023
Označenie normy: ASTM D256-23e1
Dátum vydania normy: 15.3.2023
Kód tovaru: NS-1138646
Počet strán: 20
Približná hmotnosť: 60 g (0.13 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
impact resistance, Izod impact, notch sensitivity, notched specimen, reverse notch impact,, ICS Number Code 29.035.20 (Plastic and rubber insulating materials)
Significance and Use | ||||||||||||||||
5.1?Before proceeding with these test methods, reference should be made to the specification of the material being tested. Any test specimen preparation, conditioning, dimensions, and testing parameters covered in the materials specification shall take precedence over those mentioned in these test methods. If there is no material specification, then the default conditions apply. 5.2?The pendulum impact test indicates the energy to break standard test specimens of specified size under stipulated parameters of specimen mounting, notching, and pendulum velocity-at-impact. 5.3?The energy lost by the pendulum during the breakage of the specimen is the sum of the following: 5.3.1?Energy to initiate fracture of the specimen; 5.3.2?Energy to propagate the fracture across the specimen; 5.3.3?Energy to throw the free end (or ends) of the broken specimen (toss correction); 5.3.4?Energy to bend the specimen; 5.3.5?Energy to produce vibration in the pendulum arm; 5.3.6?Energy to produce vibration or horizontal movement of the machine frame or base; 5.3.7?Energy to overcome friction in the pendulum bearing and in the indicating mechanism, and to overcome windage (pendulum air drag); 5.3.8?Energy to indent or deform plastically the specimen at the line of impact; and 5.3.9?Energy to overcome the friction caused by the rubbing of the striker (or other part of the pendulum) over the face of the bent specimen. 5.4?For relatively brittle materials, for which fracture propagation energy is small in comparison with the fracture initiation energy, the indicated impact energy absorbed is, for all practical purposes, the sum of factors 5.3.1 and 5.3.3. The toss correction (see 5.3.3) may represent a very large fraction of the total energy absorbed when testing relatively dense and brittle materials. Test Method C shall be used for materials that have an Izod impact resistance of less than 27 J/m (0.5 ft?lbf/in.). (See Appendix X4 for optional units.) The toss correction obtained in Test Method C is only an approximation of the toss error, since the rotational and rectilinear velocities may not be the same during the re-toss of the specimen as for the original toss, and because stored stresses in the specimen may have been released as kinetic energy during the specimen fracture. 5.5?For tough, ductile, fiber filled, or cloth-laminated materials, the fracture propagation energy (see 5.3.2) may be large compared to the fracture initiation energy (see 5.3.1). When testing these materials, factors (see 5.3.2, 5.3.5, and 5.3.9) can become quite significant, even when the specimen is accurately machined and positioned and the machine is in good condition with adequate capacity. (See Note 7.) Bending (see 5.3.4) and indentation losses (see 5.3.8) may be appreciable when testing soft materials. Note 7:?Although the frame and base of the machine should be
sufficiently rigid and massive to handle the energies of tough
specimens without motion or excessive vibration, the design must
ensure that the center of percussion be at the center of strike.
Locating the striker precisely at the center of percussion reduces
vibration of the pendulum arm when used with brittle specimens.
However, some losses due to pendulum arm vibration, the amount
varying with the design of the pendulum, will occur with tough
specimens, even when the striker is properly positioned.
5.6?In a well-designed machine of sufficient rigidity and mass, the losses due to factors 5.3.6 and 5.3.7 should be very small. Vibrational losses (see 5.3.6) can be quite large when wide specimens of tough materials are tested in machines of insufficient mass, not securely fastened to a heavy base. 5.7?With some materials, a critical width of specimen may be found below which specimens will appear ductile, as evidenced by considerable drawing or necking down in the region behind the notch and by a relatively high-energy absorption, and above which they will appear brittle as evidenced by little or no drawing down or necking and by a relatively low-energy absorption. Since these methods permit a variation in the width of the specimens, and since the width dictates, for many materials, whether a brittle, low-energy break or a ductile, high energy break will occur, it is necessary that the width be stated in the specification covering that material and that the width be reported along with the impact resistance. In view of the preceding, one should not make comparisons between data from specimens having widths that differ by more than a few mils. 5.8?The type of failure for each specimen shall be recorded as one of the four categories listed as follows:
For tough materials, the pendulum may not have the energy necessary to complete the breaking of the extreme fibers and toss the broken piece or pieces. Results obtained from non-break specimens shall be considered a departure from standard and shall not be reported as a standard result. Impact resistance cannot be directly compared for any two materials that experience different types of failure as defined in the test method by this code. Averages reported must likewise be derived from specimens contained within a single failure category. This letter code shall suffix the reported impact identifying the types of failure associated with the reported value. If more than one type of failure is observed for a sample material, then the report will indicate the average impact resistance for each type of failure, followed by the percent of the specimens failing in that manner and suffixed by the letter code. 5.9?The value of the impact methods lies mainly in the areas of quality control and materials specification. If two groups of specimens of supposedly the same material show significantly different energy absorptions, types of breaks, critical widths, or critical temperatures, it may be assumed that they were made of different materials or were exposed to different processing or conditioning environments. The fact that a material shows twice the energy absorption of another under these conditions of test does not indicate that this same relationship will exist under another set of test conditions. The order of toughness may even be reversed under different testing conditions. Note 8:?A documented discrepancy exists between manual and
digital impact testers, primarily with thermoset materials,
including phenolics, having an impact value of less than 54 J/m (1
ft-lb/in.). Comparing data on the same material, tested on both
manual and digital impact testers, may show the data from the
digital tester to be significantly lower than data from a manual
tester. In such cases a correlation study may be necessary to
properly define the true relationship between the
instruments.
|
||||||||||||||||
1. Scope | ||||||||||||||||
1.1?These test methods cover the determination of the resistance of plastics to standardized (see Note 1) pendulum-type hammers, mounted in standardized machines, in breaking standard specimens with one pendulum swing (see Note 2). The standard tests for these test methods require specimens made with a milled notch (see Note 3). In Test Methods A, C, and D, the notch produces a stress concentration that increases the probability of a brittle, rather than a ductile, fracture. In Test Method E, the impact resistance is obtained by reversing the notched specimen 180? in the clamping vise. The results of all test methods are reported in terms of energy absorbed per unit of specimen width or per unit of cross-sectional area under the notch. (See Note 4.) Note 1:?The machines with their pendulum-type hammers have
been standardized in that they must comply with certain
requirements, including a fixed height of hammer fall that results
in a substantially fixed velocity of the hammer at the moment of
impact. However, hammers of different initial energies (produced by
varying their effective weights) are recommended for use with
specimens of different impact resistance. Moreover, manufacturers
of the equipment are permitted to use different lengths and
constructions of pendulums with possible differences in pendulum
rigidities resulting. (See Section 5.) Be aware that other differences in
machine design may exist. The specimens are standardized in that
they are required to have one fixed length, one fixed depth, and
one particular design of milled notch. The width of the specimens
is permitted to vary between limits.
Note 2:?Results generated using pendulums that utilize a load
cell to record the impact force and thus impact energy, may not be
equivalent to results that are generated using manually or
digitally encoded testers that measure the energy remaining in the
pendulum after impact.
Note 3:?The notch in the Izod specimen serves to concentrate
the stress, minimize plastic deformation, and direct the fracture
to the part of the specimen behind the notch. Scatter in
energy-to-break is thus reduced. However, because of differences in
the elastic and viscoelastic properties of plastics, response to a
given notch varies among materials. A measure of a plastic's notch
sensitivity may be obtained with Test Method D by comparing the
energies to break specimens having different radii at the base of
the notch.
Note 4:?Caution must be exercised in interpreting the results
of these standard test methods. The following testing parameters
may affect test results significantly:
1.2?The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.3?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Note 5:?These test methods resemble ISO 180:1993 in regard to
title only. The contents are significantly different.
1.4?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|