Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Methods for Solid Filling and Treating Compounds Used for Electrical Insulation (Withdrawn 2013)
Automaticky preložený názov:
Štandardné testovacie metódy pre tuhé výplne a spracovanie zlúčeniny používané na elektrické izolácie ( Withdrawn 2013 )
NORMA vydaná dňa 1.4.2012
Označenie normy: ASTM D176-07(2012)
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.4.2012
Kód tovaru: NS-18285
Počet strán: 10
Približná hmotnosť: 30 g (0.07 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
AC loss characteristics, asphaltic compounds, bituminous compounds, coefficient of expansion or contraction, dielectric strength, fire point, flash point, fusible resins, loss on heating, melting point, penetration, permittivity (dielectric constant), softening point, solid filling compounds, solid treating compounds, specific gravity, viscosity, volume resistivity-temperature characteristics, waxes , Permittivity (dielectric constant)--electrical insulating materials, Petrolatum, Petroleum wax
| Significance and Use | ||||||||||||||||||||||||||||||
|
The melting point is useful in selecting a filling or treating compound that will not flow at the operating temperature of the device in which it will be used. It is also essential that it shall not be so high as to injure the insulation at the time of pouring. This test method is suitable for specification, classification, and for control of product uniformity. |
||||||||||||||||||||||||||||||
| 1. Scope | ||||||||||||||||||||||||||||||
|
1.1 These test methods cover physical and electrical tests for solid filling and treating compounds used for electrical insulation which are fusible to a liquid without significant chemical reaction. Compounds that are converted to the solid state by polymerization, condensation, or other chemical reaction are not included in these test methods. 1.2 These test methods are designed primarily for asphaltic or bituminous compounds, waxes, and fusible resins, or mixtures thereof, although some of these methods are applicable to semisolid types such as petrolatums. Special methods more suitable for hydrocarbon waxes are contained in Test Methods D1168. 1.3 Provide adequate ventilation when these tests involve heating. 1.4 The test methods appear in the following sections:
1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 12.1 and 31.5. Note 1—There is no similar or equivalent IEC or ISO standard. |
||||||||||||||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||||||||||||||
|
Chcete mať istotu o platnosti využívaných predpisov?
Ponúkame Vám riešenie, aby ste mohli používať stále platné (aktuálne) legislatívne predpisy
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2026-07-24 (Počet položiek: 2 290 214)
© Copyright 2026 NORMSERVIS s.r.o.