Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines
Automaticky preložený názov:
Štandardné praktiky pre infiltráciu a priesakov preberacie skúšky nainštalovaných prefabrikovaných betónových potrubia kanalizačného potrubia
NORMA vydaná dňa 1.6.2009
Označenie normy: ASTM C969-02(2009)
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.6.2009
Kód tovaru: NS-15896
Počet strán: 3
Približná hmotnosť: 9 g (0.02 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
Concrete pipe, Exfiltration rate, Filtration performance, Infiltration rate, Pond/canal/reservoir/ditch linings, Sewer pipe (concrete), Water analysis, Water infiltration/exfiltration, Water penetration, ICS Number Code 23.040.50 (Pipes and fittings of other materials)
| Significance and Use | ||
|
This is not a routine test. The values recorded are applicable only to the sewer being tested and at the time of testing. |
||
| 1. Scope | ||
|
1.1 This practice covers procedures for testing installed precast concrete pipe sewer lines using either water infiltration or exfiltration acceptance limits to demonstrate the integrity of the installed materials and construction procedure. 1.2 This practice is the inch-pound companion to Practice C 969M; therefore, no SI equivalents are presented in the practice. Note 1—The owner shall specify the following: who will conduct, observe, and furnish labor, furnish material and measuring devices, and pay for the tests; who is responsible for determining local groundwater conditions; and which test is to be conducted, that is, an infiltration test or an exfiltration test. Note 2—The user of this practice is advised that test criteria presented in this practice are similar to those in general use. Pipe, 24-in. diameter or larger, may be accepted by visual inspection when testing for infiltration. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||
| 2. Referenced Documents | ||
|
Historická
1.7.2013
Historická
1.2.2013
Historická
1.2.2013
Historická
1.2.2014
Historická
1.2.2014
Historická
1.2.2014
Poskytovanie aktuálnych informácií o legislatívnych predpisoch vyhlásených v Zbierke zákonov od roku 1945.
Aktualizácia 2x v mesiaci !
Chcete vedieť viac informácii ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2026-07-08 (Počet položiek: 2 286 190)
© Copyright 2026 NORMSERVIS s.r.o.