Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength, and Perforated
NORMA vydaná dňa 1.9.2022
Označenie normy: ASTM C700-18(2022)
Dátum vydania normy: 1.9.2022
Kód tovaru: NS-1071843
Počet strán: 4
Približná hmotnosť: 12 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
This specification covers extra strength and standard strength vitrified clay pipe and fittings to be used for the conveyance of sewage, industrial wastes, and storm water; and extra strength perforated and standard strength perforated vitrified clay pipe to be used for underdrainage, filter fields, leaching fields, and similar subdrainage installations. Vitrified clay pipe shall be manufactured from fire clay, shale, surface clay, or a combination of these materials that, when formed into pipe and fired to suitable temperatures. Pipe shall meet the bearing strength requirements prescribed. The manufacturer shall at his option, apply either a hydrostatic pressure test or an absorption test to all of the test specimens in each size and run of the pipe. The absorption of vitrified clay pipe shall not exceed 8%. The acid resistance test is used to determine the resistance of pipe to the action of acids encountered in sanitary sewers.
Keywords:
absorption test, bearing strength, bell, chemical resistance, clay, corrosion resistance, drains, fittings, leachate, leaching fields, perforated pipe, pipe, plain end, sewers, spigot, vitrified,, ICS Number Code 23.040.50 (Pipes and fittings of other materials)
1. Scope | ||||||||||
1.1?This specification establishes the criteria for acceptance, prior to installation, of extra strength and standard strength vitrified clay pipe and fittings to be used for the conveyance of sewage, industrial wastes, and storm water; and extra strength perforated and standard strength perforated vitrified clay pipe to be used for underdrainage, filter fields, leaching fields, and similar subdrainage installations. 1.2?The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. Note 1:?Attention is called to Specification C425, Test Method C828, Test Method C1091, Test Methods C301, and Terminology C896.
1.3?The following precautionary caveat pertains only to the Test Method portion, 5.2 5.2.3.2 of this standard: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||
2. Referenced Documents | ||||||||||
|
Posledná aktualizácia: 2024-11-25 (Počet položiek: 2 206 719)
© Copyright 2024 NORMSERVIS s.r.o.