Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Specification for Nonreinforced Concrete Irrigation Pipe with Rubber Gasket Joints
Automaticky preložený názov:
Štandardné špecifikácie pre Nonreinforced Concrete zavlažovanie rúrka s gumovým tesnením spojov
NORMA vydaná dňa 1.9.2011
Označenie normy: ASTM C505-11
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.9.2011
Kód tovaru: NS-13732
Počet strán: 5
Približná hmotnosť: 15 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
absorption, acceptance criteria, concrete, design, drainage, gasket tests, gaskets, hydrostatic, irrigation, joints, manufacture, nonreinforced, pipe, pressure, rubber gaskets, tests, three-edge bearing: Concrete pipe (nonreinforced)--specifications, Gaskets--specifications, Irrigation piping--specifications, Joints (concrete applications)--specifications, Pressure pipelines/piping systems--specifications, Watertight joints
| 1. Scope | |||||||||||||||||||||||||||||||||||||||||||||
|
1.1 This specification covers nonreinforced concrete pipe with rubber gasket joints to be used for the conveyance of irrigation water with working pressures, including hydraulic transients, as shown in Table 1. 1.2 A complete metric companion to Specification C505 has been developedC505M; therefore, no SI equivalents are presented in this specification. Note 1—This specification is for manufacturing and purchase only and does not include requirements for bedding, backfill, installation, or field repairs. The owner is cautioned that he must correlate field conditions with the characteristics of the pipe specified and provide inspection during installation. TABLE 1 Standard Dimensions, Working Pressures, and Test Requirements
A Thinner walls are not prohibited on pipe units not over 4 ft in length, but the thickness of such walls shall not be less than the internal diameter divided by 10. B With the exception of 21 and 24-in. pipe, higher working pressures are not prohibited to be used up to a maximum of 50 ft for 6 through 12-in. diameters, and 40 ft for 15 through 18-in. diameters. In these cases the strength of the pipe shall be increased to give minimum internal hydrostatic test pressures of at least three times the design working pressure when tested as specified in 10.4. C For hydrostatic test requirements, refer to 10.4. |
|||||||||||||||||||||||||||||||||||||||||||||
| 2. Referenced Documents | |||||||||||||||||||||||||||||||||||||||||||||
|
Posledná aktualizácia: 2026-06-28 (Počet položiek: 2 284 473)
© Copyright 2026 NORMSERVIS s.r.o.