Standard Test Method for Effectiveness of Pozzolans or Ground Blast-Furnace Slag in Preventing Excessive Expansion of Concrete Due to the Alkali-Silica Reaction
Automaticky preložený názov:
Štandardná skúšobná metóda pre účinnosti puzolán alebo mleté vysokopecnej trosky pri prevencii prílišnou expanziou Betón Vzhľadom k tomu, alkalických Silica reakcie
NORMA vydaná dňa 15.10.2011
Označenie normy: ASTM C441/C441M-11
Poznámka: NEPLATNÁ
Dátum vydania normy: 15.10.2011
Kód tovaru: NS-13405
Počet strán: 3
Približná hmotnosť: 9 g (0.02 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
alkali-silica reaction, concrete, expansion, fly ash, ground blast-furnace slag, mortar, pozzolan, silica fume, ICS Number Code 91.100.30 (Concrete and concrete products)
Significance and Use | ||||||||||||||
This test method may be used as a preliminary or screening test to evaluate the relative effectiveness of a number of different materials being considered for use to prevent excessive expansion due to alkali-silica reaction. This test method may also be used to evaluate materials proposed for use on a particular job to prevent excessive expansion due to alkali-silica reaction, by testing in the quantity and in combination with the cement or cements to be used on the job. This test method does not assess the suitability of pozzolans or slag for use in concrete. These materials should comply with Specification C618, Specification C989 or Specification C1240. |
||||||||||||||
1. Scope | ||||||||||||||
1.1 This test method covers the determination of the effectiveness of pozzolans or slag in preventing the excessive expansion caused by reaction between aggregates and alkalies in portland cement mixtures. The evaluation is based on the expansion developed in mortar bars by a combination of portland cement and a pozzolan or slag, made with reactive aggregates (borosilicate glass), during storage under prescribed conditions of test. 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-11-03 (Počet položiek: 2 209 203)
© Copyright 2024 NORMSERVIS s.r.o.