Standard Specification for Circular Precast Concrete Culvert, Storm Drain, and Sewer Pipe for Pipe Jacking
NORMA vydaná dňa 1.12.2021
Označenie normy: ASTM C1885-21
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.12.2021
Kód tovaru: NS-1044302
Počet strán: 5
Približná hmotnosť: 15 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
circular pipe, culvert, D-load, pipe, jacking, reinforced concrete, sewer pipe, storm drain,, ICS Number Code 23.040.50 (Pipes and fittings of other materials)
| 1. Scope |
|
1.1?This specification covers the manufacturing requirements for circular concrete pipe that is intended to be installed using pipe jacking techniques. The typical use of this type of pipe is for the conveyance of sewage, industrial wastes, storm water, utilities, or personnel. 1.2?The requirements of this specification are intended to supplement the existing manufacturing standards for precast concrete pipe and provide the additional manufacturing details required for pipe that will be installed using jacking techniques. The parent manufacturing standard for the concrete pipe is denoted as the designated concrete pipe manufacturing standard throughout this document. The requirements included within shall supplement the designated concrete pipe manufacturing standard when the concrete pipe is to be used for jacking. Note 1:?This specification is a manufacturing and purchase
specification for concrete pipe installed using jacking techniques,
to be utilized in conjunction with the designated concrete pipe
manufacturing standard. It is possible that such pipe will require
a special design to withstand the anticipated longitudinal loading.
Additional calculations and information beyond what is required for
a direct bury pipe are required to establish maximum jacking
forces. For calculating allowable jacking forces, ASCE 27 may be
referenced.
Note 2:?This standard may be used to supplement existing
standards for precast concrete pipe when the pipe will be installed
using trenchless methods. Such designated concrete pipe standards
include, but are not limited to: C14, C76, C361, C655, C985, C1417, C1765, and C1846/C1846M.
1.3?There are many forms of pipe jacking. The most advanced of these, and in a category all its own, is microtunneling pipe. With the highly accurate guidance systems used in microtunneling, the pipes are utilized in longer push lengths and more challenging configurations and soil conditions. This standard does not address concrete pipe used for microtunneling. For concrete pipe used in microtunneling, the engineer, producer, and installer are encouraged to work together in establishing the specific needs of each project. 1.4?There are applications where concrete pipe is utilized as a carrier pipe and is pushed through a casing after the soil has already been removed. These applications are not specifically addressed by this standard since the requirements for these types of installations differ from those for a typical jacking installation. 1.5?UnitsThe values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard. 1.6?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |