Standard Test Method for Rapid Assessment of Static Segregation Resistance of Self-Consolidating Concrete Using Penetration Test
Automaticky preložený názov:
Štandardná skúšobná metóda pre rýchle statického posúdenia odolnosti proti segregácii Self-Konsolidácia betón Použitie penetračný test
NORMA vydaná dňa 1.4.2014
Označenie normy: ASTM C1712-14
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.4.2014
Kód tovaru: NS-12275
Počet strán: 6
Približná hmotnosť: 18 g (0.04 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
penetration depth, penetration test, rapid test, segregation, self-consolidating concrete, stability, static segregation resistance, ICS Number Code 91.100.30 (Concrete and concrete products)
Significance and Use | ||||||||||||||
5.1 This test method is for the rapid assessment of the static segregation resistance of self-consolidating concrete. 5.2 The method is useful for rapid assessment of the static segregation resistance of self-consolidating concrete during mixture development in the laboratory as well as prior to placement of the mixture in the field. Test Method C1610/C1610M for static segregation of SCC is not sufficiently rapid, and the non-mandatory Visual Stability Index as determined through the procedure described in Appendix X1 of Test Method C1611/C1611M is highly subjective and qualitative. 5.3 Appendix X1 provides non-mandatory criteria that may be used to indicate the degree of static segregation resistance of self-consolidating concrete mixtures. |
||||||||||||||
1. Scope | ||||||||||||||
1.1 This test method covers the rapid assessment of static segregation resistance of normal-weight self-consolidating concrete (SCC). The test does not measure static segregation resistance directly, but provides an assessment of whether static segregation is likely to occur. 1.2 The test apparatus and protocol were developed based on tests with SCC mixtures containing saturated surface dry (SSD) coarse aggregates ranging in relative density from 2.67 to 2.79 and in nominal maximum size from 9.5 mm to 25 mm. For SCC mixtures outside these ranges, testing is recommended to establish a correlation between penetration depth and static segregation measured in accordance with Test Method C1610/C1610M. This test method shall not be used to assess the static segregation resistance of self-consolidating concrete containing lightweight aggregates or heavyweight aggregates without prior testing to establish a correlation. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes shall not be considered as requirements of the standard. 1.5 This standard does not
purport to address all of the safety concerns, if any, associated
with its use. It is the responsibility of the user of this standard
to establish appropriate safety and health practices and determine
the applicability of regulatory limitations prior to use.
(
Standard Terminology Relating to Concrete
and Concrete Aggregates (Includes all amendments and changes
10/14/2021). Standard Test Method for Slump of
Hydraulic-Cement Concrete Standard Practice for Sampling Freshly
Mixed Concrete Standard Test Method for Air Content of
Freshly Mixed Concrete by the Volumetric Method Standard Practice for Making and Curing
Concrete Test Specimens in the Laboratory Standard Test Method for Static
Segregation of Self-Consolidating Concrete Using Column
Technique Standard Test Method for Slump Flow of
Self-Consolidating Concrete |
Historická
1.8.2010
Historická
1.4.2012
Historická
1.6.2011
Historická
1.7.2012
Historická
1.2.2013
Historická
1.1.2013