Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practice for Alternate Actinide Calibration for Inductively Coupled Plasma-Mass Spectrometry
Automaticky preložený názov:
Štandardné praktiky pre alternatívne aktinoidové kalibráciu pre indukčne viazanou plazmou-hmotnostnej spektrometrie
NORMA vydaná dňa 1.1.2014
Označenie normy: ASTM C1590-04(2014)
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.1.2014
Kód tovaru: NS-11947
Počet strán: 6
Približná hmotnosť: 18 g (0.04 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
actinides, inductively coupled plasma-mass spectrometry (ICP-MS), mass bias, thorium, uranium, ICS Number Code 71.040.50 (Physicochemical methods of analysis)
Significance and Use | ||||||||||||||
5.1 One of the benefits of this standard practice is the ability to calibrate for the analysis of highly radioactive actinides using calibration standards at much lower specific activities (that is, 232Th and 238U). Environmental laboratories may find this standard practice useful if facilities are not available to handle the highly radioactive standards of the individual actinides of interest. 5.2 The degree of actual mass bias is variable and is dependent upon instrument tune parameters. This standard practice uses universal interference equations to derive a mass bias correction that is specific to the instrument parameters and tune used for sample data acquisition and not based on a historical average. 5.3 Mass bias correction uses the instrument software interference equations and does not require additional subsequent off-line calculations. 5.4 The methodology that this standard practice is based on has been used for the determination of 232Th and 237Np in enriched uranium solutions and the determination of 241Am in plutonium and uranium legacy oxides following dissolution and ion extraction chromatography separation. |
||||||||||||||
1. Scope | ||||||||||||||
1.1 This practice provides guidance for an alternate linear calibration for the determination of selected actinide isotopes in appropriately prepared aqueous solutions by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). This alternate calibration is mass bias adjusted using thorium-232 (232Th) and uranium-238 (238U) standards. One of the benefits of this standard practice is the ability to calibrate for the analysis of highly radioactive actinides using calibration standards at much lower specific activities. Environmental laboratories may find this standard practice useful if facilities are not available to handle the highly radioactive standards of the individual actinides of interest. 1.2 The instrument response for a series of determinations of known concentration of 232Th and 238U defines the mass versus response relationship. For each standard concentration, the slope of the line defined by 232Th and 238U is used to derive linear calibration curves for each mass of interest using interference equations. The mass bias corrected calibration curves, although generated from interference equations, are specific to the instrument operating parameters and tuning in effect at the time of data acquisition. Because interference equations are part of the normal ICP-MS manufacturer's software package, this calibration methodology is widely applicable. 1.3 For this standard practice, the actinide atomic mass range that has been studied is from amu 232–244. Guidance for an extended range of amu 228–248 is given in this practice. 1.4 Using this practice, analyte concentrations are reported at each amu and not by element total (that is, 239Pu versus plutonium). 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Historická
1.10.2013
Historická
15.7.2007
Historická
1.12.2012
Historická
1.2.2014
Historická
1.6.2011
Historická
1.10.2010
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-12-22 (Počet položiek: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.