Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Determination of Installed Thickness of Pneumatically Applied Loose-Fill Building Insulation
NORMA vydaná dňa 1.3.2023
Označenie normy: ASTM C1374-18(2023)
Dátum vydania normy: 1.3.2023
Kód tovaru: NS-1137920
Počet strán: 5
Približná hmotnosť: 15 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
cellulose, cellulosic fiber, fibrous glass, installed thickness, insulation, loose fill, mineral fiber, pneumatically applied, thermal insulation, thickness,, ICS Number Code 91.100.60 (Thermal and sound insulating materials),91.120.10 (Thermal insulation of buildings)
Significance and Use | ||||||||||
5.1?This test method was designed to give the manufacturer of loose-fill insulation products a way of determining what the initial installed thickness should be in a horizontal open attic for pneumatic applications. 5.2?The installed thickness value developed by this test method is intended to provide guidance to the installer in order to achieve a minimum mass/unit area for a given R-value. 5.3?For the purpose of product design, testing should be done at a variety of Note 1:?For quality control purposes, testing may be done at one 5.4?Specimens are blown in a manner consistent with the intended installation procedure. Blowing machine settings should be representative of those typically used for field application with that machine. 5.5?The material blown for a given R-value as part of the installed thickness test equals the installed mass/unit area times the test chamber area. This mass can be calculated from information provided on the package label at the R-value prescribed. |
||||||||||
1. Scope | ||||||||||
1.1?This test method covers determination of the installed thickness of pneumatically applied loose-fill building insulations prior to settling by simulating an open attic with horizontal blown applications. 1.2?This test method is a laboratory procedure for use by manufacturers of loose-fill insulation for product design, label development, and quality control testing. The apparatus used produces installed thickness results at a given mass/unit area. 1.3?This test method is not the same as the design density procedures described in Test Methods C520 or Specifications C739 or C764. 1.4?The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.6?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||
2. Referenced Documents | ||||||||||
|
Posledná aktualizácia: 2024-11-22 (Počet položiek: 2 206 568)